70HF(R) Series High-reliability discrete products and engineering services since 1977 STANDARD RECOVERY DIODES 70 AMP FEATURES Available as “HR” (high reliability) screened per MIL-PRF-19500, JANTX level. Add “HR” suffix to base part number. Available as non-RoHS (Sn/Pb plating), standard, an.
Available as “HR” (high reliability) screened per MIL-PRF-19500, JANTX level. Add “HR” suffix to base part number.
Available as non-RoHS (Sn/Pb plating), standard, and as RoHS by adding “-PBF” suffix.
MAXIMUM RATINGS Parameter
Maximum average forward current
Symbol IF(AV)
Test Conditions
70HF(R)
10 to 120
140 to 160
70 @ TC = 140°C
70 @ TC = 110°C
Units Amps
Maximum RMS forward current Maximum peak, on cycle, non-repetitive forward surge current Maximum I2t for fusing
Maximum repetitive peak reverse voltage Junction temperature range
IF(RMS) IFSM
I2t VRRM
TJ
@ 50Hz @ 60Hz
@ 50H.