DatasheetsPDF.com

2R090-4S Datasheet PDF


Part Number 2R090-4S
Manufacturer RuiLongYuan
Title (2R-4S Series) Gas Discharge Tubes
Description ELECTRONICS Circuit Protection System Gas Discharge Tubes 2R-4S Series Specifications are subject to change without notice. Please refer to http:...
Features 1. RoHS & HF compliant 2. SMD Structure 3. DC Spark-over voltage: 75~2000V 4. Low Capacitance 5. Agency Recognition : UL/ cUL 6. Operating temperature:-30°C ~ +85°C Storage temperature:-40°C ~ +115°C Recommended Applications 1. Cable Modem 2. xDSL 3. Set-Top Box 4. TV sets 5. Power supplier 6. Cons...

File Size 392.78KB
Datasheet 2R090-4S PDF File








Similar Ai Datasheet

2R090-4S : 2R-4S SERIES GAS DISCHARGE TUBES Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA.The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality Surge Protection Devices (SPD). Features ! Size:4.2mm*4.0mm ! DC Spark-over voltage: 75~2000V ! Stable breakdown voltage. ! High insulation resistance. ! Low capacitance (1pF) ! High holdover voltage. ! Lar.

2R090-5S : ELECTRONICS Circuit Protection System Gas Discharge Tubes 2R-5S Series Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. Gas Discharge Tubes - 2R-5S Series GDT introduction:Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA. The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality .

2R090-5S : 2R-5S SERIES SURFACE MOUNT GAS DISCHARGE TUBES GDT introduction:Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA. The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality Surge Protection Devices (SPD). Features ! RoHS & HF compliant ! SMD Structure ! DC Spark-over voltage: 75~1000V ! Low Capacitance ! Agency Recognition : UL/ cUL ! Operating tem.

2R090A-6S : ELECTRONICS Circuit Protection System Gas Discharge Tubes 2R-6S Series Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. Gas Discharge Tubes - 2R-6S Series GDT introduction:Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA. The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality .

2R090A-6S : 2R-6S SERIES GAS DISCHARGE TUBES Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA.The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality Surge Protection Devices (SPD). Features D Size:4.2mm*6.0mm D DC Spark-over voltage: 75~3000V D Stable breakdown voltage. D High insulation resistance. D Low capacitance (1pF) D High holdover voltage. D Lar.

2R090B-8S : 2RB-8S SERIES GAS DISCHARGE TUBES Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA.The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality Surge Protection Devices (SPD). Features D Size:8.3mm*6.0mm D DC Spark-over voltage: 75~800V D Stable breakdown voltage. D High insulation resistance. D Low capacitance (1pF) D High holdover voltage. D Large.

2R090L5050 : SHANGHAI SEMITECH SEMICONDUCTOR CO., LTD 2RxxxL5050 Series Gas Discharge Tubes-2RxxxL5050 Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes. The ceramic envelope and with nickel connectors allow for high loads and SEMITCH offers products that function at 20KA, 40KA,50KA,60KA,100KA & 150KA. The breakdown voltages of the devices have a wide range (up to 20% tolerance). Major applications are high frequency telecommunication lines, stations, security systems, HID and high quality Surge Protection Devices(SPD). Features l RoHS & HF compliant l Size: 5.0mm*5.0mm l DC Spark-over voltage: 75~1000V l Stable breakdown voltage .

2R090SA-6 : Gas Discharge Tube 2R075~2R800SA-6 Series GDTs (Gas Discharge Tubes) are placed in front of, and in parallel with, sensitive telecom equipment such as power lines, communication lines, signal lines and data transmission lines to help protect them from damage caused by transient surge voltages that may result from lightning strikes and equipment switching operations.These devices do not influence the signal in normal operation. However, in the event of an overvoltage surge, such as a lightning strike, the GDT switches to a low impedance state and diverts the energy away from the sensitive equipment. GDTs offer a high level of surge protection, a broad voltage range, low capacitance, and many .

2R090TB-5 : ELECTRONICS Circuit Protection System Gas Discharge Tubes 2RB-5 Series Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. Gas Discharge Tubes - 2RB-5 Series GDT introduction:Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA. The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality .




Since 2006. D4U Semicon,
Electronic Components Datasheet Search Site. (Privacy Policy & Contact)