Power Line Filters Dual Stage
12-MMF & 12-MMB Series Features
I Suitable for products that must conform to FCC regulatio...
Power Line Filters Dual Stage
12-MMF & 12-MMB Series Features
I Suitable for products that must conform to FCC regulations
I Excellent attenuation for high
voltage impulse I Metal case provides effective EMI shielding I Two stages for excellent filtering characteristics I Structure provides effective shielding for noise
generated both externally and internally I Operating temperature: -40°C to +85°C I High performance
Applications
I Digital equipment I Personal computers and peripherals I Measuring instruments and medical equipment I Telecommunications equipment I Equipment requiring very high noise attenuation
Circuit Diagram
Circuit 1
Circuit 2
Specifications
Model
Rated
Voltage (@ 50/60Hz)
Rated Current
Leakage Current (Max.)
Circuit Diagram
12-MMF-003-11-F 12-MMF-006-11-F 12-MMF-010-11-F 12-MMB-015-11-G 12-MMB-020-11-D 12-MMB-030-11-D 12-MMB-040-11-B 12-MMB-040-11-E 12-MMB-050-11-H
120/250VAC
3A 6A 10A 15A 20A 30A
40A
50A
1.5mA
1
1 2 1
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test
voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max.
Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 6.0 ounces (170 grams)
Figure
A
C B D E F
Temperature Rise (Max.) 30°C
API TECHNOLOGIES 8061 Avonia Rd. Fairview, PA 16415 Ph: 814-474-1571 Fax: 814-474-3110 eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach,...