946 Series Relay
FEATURES
● UL safety approval. ● Standard type & High sensitivity type available. ● 2 Amps super miniat...
946 Series Relay
FEATURES
● UL safety approval. ● Standard type & High sensitivity type available. ● 2 Amps super miniature relay. ● Conforms to FCC rules & regulation part 68. ● Surge strength: 1500 VAC. ● 1 Form C (SPDT) contact. ● Nominal power 200mW~360mW. ● Operating power 110mW~200mW. ● DIL pitch terminal. ● Washable Type (ultrasonic cleaning is not recommended).
UL FILE NO: E162117
CONTACT RATINGS
●Contact Arrangement………………….1 Form C (SPDT) ●Max. Switching Power………………...125VA 60W ●Max. Switching
Voltage……………….125VAC 30VDC ●Max. Switching Current………. ……...2A ●Contact Resistance…………………….≤100mΩ ●Rating Load ……………………………1A/125VAC …....……………………....2A/30VDC ●Contact Material ……………………....Ag Alloy
12 10 8
946 Referential Data Timing
Time (msec.)
Operate Time 6 4 Release Time 2
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Coil Power (W)
CHARACTERISTICS
●Electrical Life………………………….1×105 ●Mechanical Life………………………..1×107 ●Initial Insulation Resistance…………...Min. 100MΩ 500VDC ●Contact Resistance (Initial)……..…......≤100mΩ ●Operate Time…………………………..≤6ms ●Release Time…………………………..≤3ms ● Initial Dielectric Strength ……..50/60Hz 500VAC 1 min. (between open contacts) ……..50/60Hz 500VAC 1 min. (between contacts and coil) ● Vibration Resistance ………Malfunction: 10 to 55Hz at Double Amplitude of 1.5mm ………Destructive: 10 to 55Hz at Double Amplitude of 1.5mm ● Shock Resistance ………Malfunction: 10G (11ms) / Destructive: 100G (6ms) ●Ambient Temperature………………….-20℃~+40℃ ●Relative Humidity……………………..85% at ...