Data Sheet ADA4530-1
Femtoampere Input Bias Current Electrometer Amplifier
FEATURES
PIN CONNECTION DIAGRAM
► Low inpu...
Data Sheet ADA4530-1
Femtoampere Input Bias Current Electrometer Amplifier
FEATURES
PIN CONNECTION DIAGRAM
► Low input bias current ► ±20 fA maximum at TA = 25°C (guaranteed at production test) ► ±20 fA maximum at −40°C < TA < +85°C ► ±250 fA maximum at −40°C < TA < +125°C (guaranteed at production test)
► Low offset
voltage: 50 µV maximum over specified CMRR range
► Offset
voltage drift: ±0.13 µV/°C typical, ±0.5 µV/°C maximum
► Integrated guard buffer with 100 µV maximum offset
► Low
voltage noise density: 14 nV/√Hz at 10 kHz
► Wide bandwidth: 2 MHz unity-gain crossover
► Supply
voltage: 4.5 V to 16 V (±2.25 V to ±8 V)
► Operating temperature: −40°C to +125°C
► Long-term offset
voltage drift (10,000 hours): 0.5 µV typical
► Temperature hysteresis: 1.5 µV typical
Figure 1.
APPLICATIONS
► Laboratory and analytical instrumentation: spectrophoto-meters, chromatographs, mass spectrometers, and potentiostatic and amperostatic coulometry
► Instrumentation: picoammeters and coulombmeters
► Transimpedance amplifier (TIA) for photodiodes, ion chambers, and working electrode measurements
► High impedance buffering for chemical sensors and capacitive sensors
GENERAL DESCRIPTION
The ADA4530-1 is a femtoampere (10−15 A) level input bias current operational amplifier suitable for use as an electrometer that also includes an integrated guard buffer. It has an operating
voltage range of 4.5 V to 16 V, enabling it to operate in conventional 5 V and 10 V single supply systems as well ...