SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . .1 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . 3 REFRIGERANT SYSTEM DIAGRAM . . . . 4 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . 5 INDOOR PCB CIRCUIT DIAGRAM . . . . . . 6 OUTDOOR PCB CIRCUIT DIAGRAM . . . 9 ERROR CONTENTS . . . . . . . . . . . . . . . . . 11 PARTS (Indoor unit) . . . . . . . . . . . . . . . . . . 12 PARTS (Outdoor unit) . . . . . . . . . . . . . . . . .16 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . 20
http://www.Datasheet4U.com
SPECIFICATIONS
ELECTRICAL DATA
TYPE INDOOR UNIT OUTDOOR UNIT COOLING CAPACITY HEATING CAPACITY POWER SOURCE FREQUENCY RUNNING CURRENT INPUT WATTS E.E.R. COP Cooling Heating Cooling Heating Cooling Heating ASYA07LGC AOYR07LGC 2.10 kW 3.00 kW 230 V 50 Hz 2.4 A 3.2 A 0.470 kW 0.660 kW 4.47 kW/kW 4.55 kW/kW 1.0 L/h 750 m3/h
750 m3/h
Cool & heat inverter ASYA09LGC AOYR09LGC 2.50 kW 3.20 kW 230 V 50 Hz 3.2 A 3.7 A 0.630 kW 0.750 kW 3.97 kW/kW 4.27 kW/kW 1.3 L/h 750 m3/h
750 m3/h
ASYA12LGC AOYR12LGC 3.40 kW 4.00 kW 230 V 50 Hz 4.3 A 4.6 A 0.895 kW 0.970 kW 3.80 kW/kW 4.12 kW/kW 1.8 L/h 750 m3/h
750 m3/h
MOISTURE REMOVAL AIR CIRCULATION Cooling HIGH Heating MAXIMUM CURRENT Cooling Heating
6.0 A 7.5 A
6.0 A 7.5 A
6.5 A 9.0 A
FAN MOTOR
POWER SOURCE High speed INDOOR UNIT Middle speed Cooling Low spee...