AZ2501P
50 AMP LATCHING POWER RELAY
FEATURES
• 50 Amp switching • Heavy loads to 13850 VA • 4 kV dielectric strength • 8...
AZ2501P
50 AMP LATCHING POWER RELAY
FEATURES
50 Amp switching Heavy loads to 13850 VA 4 kV dielectric strength 8 mm creepage distance Manual switch available Epoxy sealed version available UL, CUR file E44211
CONTACTS
Arrangement SPDT (1 Form C), SPST (1 Form A)
Ratings
Resistive load:
Rated Load UL, CUR
Max. switched power: 13850 VA Max. switched current: 50 A Max. switched
voltage: 440 VAC
1 Form A (SPST) 50 A at 277 VAC, resistive, 70°C, 100k cycles 20 A at 347 VAC, resistive, 70°C, 30k cycles 5000 W at 240 VAC, tungsten, 40°C, 30k cycles 120 LRA / 20 FLA, at 120 VAC, 40°C, 30k cycles 102 LRA / 17 FLA, at 240 VAC, 40°C, 30k cycles 84 LRA / 14 FLA, at 277 VAC, 40°C, 30k cycles
1 Form C (SPDT) 40 A at 277 VAC, general use, 70°C, 30k cycles
Material Resistance
Silver tin oxide
< 50 milliohms initially (at rated current,
voltage drop method)
COIL
Power At Pickup
Voltage (typical)
Temperature
.96 W single coil 1.9 W dual coil
Max. 105°C (221°F)
NOTES
1. All values at 20°C (68°F). 2. Relay may pull in with less than “Must Operate” value. 3. Specifications subject to change without notice. 4. Initial state of contacts may be changed during transportation or shock!
GENERAL DATA
Life Expectancy Mechanical Electrical
Minimum operations 1 x 106 1 x 105 at 50 A 250 VAC Res. (SPST)
Set and Reset Pulse Duration
50 ms minimum at nominal coil
voltage
Set Time (typical)
15 ms at nominal coil
voltage
Reset Time (typical) 15 ms at nominal coil
voltage
Diele...