Series B48-2T, B48-2
35-50 Amp • DIODE Modules
• Single and Three Phase Circuits • Up to 1600 Volt Blocking Standard
Sin...
Series B48-2T, B48-2
35-50 Amp DIODE Modules
Single and Three Phase Circuits Up to 1600 Volt Blocking Standard
Single- and three-phase diode circuits come in a panel mount package that provides 2500 Vrms isolation from the terminals to the ceramic base. Available in ratings up to 1600 Volts, all models are UL recognized (file no. E72445). Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability.
PART NUM BER IDENTIFICATION Series Type B48 Cir cuit Type 1-5 (see schematic diagrams) Vol t ag e B - 400 (120Vac) C - 600 (240Vac) E - 1000 (380Vac) F - 1200 (480Vac) G - 1400 (530Vac) H - 1600 (600Vac) Case S t yle -2T (Standard) -2 With Isolation Barriers
Exam ple : B48 3C-2T
M ECHANICAL DIM ENSIONS
All dimensions are in inches (millimeters)
ELECTRICAL SPECIFICATIONS
SYMBOL SPECIFICATION
RA TINGS SINGLE PHASE THREE PHASE 35A
1.25V @ 35A
ID B48-2T
2.50 (63.5) 1.90 (48.2) MOUNTING HOLE/SLOT 0.21 (5.2) DIA.
Maximum DC Output Current (Tc = 85˚C) Maximum
Voltage Drop @ Amps Peak Operating Junction Temperature Range
50A
1.35V @ 50A
VF TJ
-40˚C to +125˚C 400 600 1000 1200 1400 1600 600A 1500 0.9˚C/W 2500 VRMS (120 Vac) (240 Vac) (380 Vac) (480 Vac) (530 Vac) (600 Vac) 600A 1500 0.9˚C/W 2500 VRMS
C L 1.00 1.25 (25.4 ) (31.7)
VRRM
Repetitive Peak Reverse
Voltage (Ac Line)
.50 (12.7)
C L
.25 TERMINAL (6.3)
ITSM
.55 (14.0)
Maximum Non-Repetitive Surge Current (1/2Cycle, 60Hz) Maximum I2T for Fusing (t=8.3ms) [A2sec] Maximum T...