PTC thermistors
Limit temperature sensors, probe assemblies
Series/Type: Date:
B59801 March 2006
© EPCOS AG 2006. Rep...
PTC thermistors
Limit temperature sensors, probe assemblies
Series/Type: Date:
B59801 March 2006
© EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Sensors Limit temperature sensors, probe assemblies
D801
Applications Limit temperature sensor
Features Insulated screw-type metal case Thread M3 Tinned leads Marked with nominal threshold temperature and type designation Characteristics for nominal threshold temperatures TNTT = 90 to 120 °C conform with DIN 44081 Fast response due to small dimensions RoHS-compatible
Delivery mode Bulk
Dimensional drawing
Dimensions in mm
General technical data
Max. operating
voltage Max. measuring
voltage Rated resistance Insulating test
voltage Thermal threshold time Operating temperature range Operating temperature range
(TA = 0 ... 40 °C) (TA = 25 °C ... TNTT +23 K) (VPTC ≤ 2.5 V)
(V ≤ Vmeas,max) (V = Vmax)
Vmax Vmeas,max RR Vins ta Top Top
30 7.5 ≤100 1.5 <20 40/ TNTT +23 0/+40
VDC VDC Ω kVAC s °C °C
Please read Important notes and Cautions and warnings at the end of this document.
Page 2 of 7
Sensors Limit temperature sensors, probe assemblies
D801
Electrical specifications and ordering codes
TNTT °C
R
(TNTT 5 K) (VPTC ≤ 2.5 V) Ω
R
(TNTT + 5 K) (VPTC ≤ 2.5 V) Ω
R
(TNTT + 15 K) (VPTC ≤ 7.5 V) Ω
R
(TNTT + 23 K) (VPTC ≤ 2.5 V) Ω
Ordering code
60 ≤ 570 ≥ 570 -
≥ 10 k
B59801D0060A0...