Data Sheet
220VAC Input/24VDC (150mA) Output
Non-Isolated AC/DC Converter
BP5047A24
Absolute Maximum Ratings
Paramete...
Data Sheet
220VAC Input/24VDC (150mA) Output
Non-Isolated AC/DC Converter
BP5047A24
Absolute Maximum Ratings
Parameter
Input
voltage Maximum output
voltage ESD endurance Operating temperature range Storage temperature range
Symbol
Vi IoMAX Vsurge Topr Tstg
Limits
358 150
2 −20 to +80 −25 to +105
Unit
V mApk
kV °C °C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input
voltage range
Vi 249 311 358 V
Output
voltage
Vo 23.0 24.0 25.8 V Vi=311V, Io=100mA
Output current Line regulation Load regulation Output ripple
voltage Power conversion effciency
Io Vr Vl Vp
η
0 −0.20 −0.20
− 65
− 0.05 0.05 0.07 78
150 0.20 0.20 0.15
−
mA V V Vp-p %
Vi=311V
∗1
Vi=249 to 358V, Io=100mA
Vi=311V, Io=0 to 100mA ∗2 Vi=311V, Io=100mA
Vi=311V, Io=150mA
∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Please refer to Load regulation, Conversion effciency.
Application Circuit
BP5047A24
Be sure to use fuse for safety.
12 10 7 5 3 1
DC motor
Ii D1
R1
+ Vi ZNR − C1
FUSE C3
Io L1 +
− C2 Vo
Pin No.
Function
1 Output terminal Vo(24V)
2 Skip
3 Choke coil connect
4 Skip
5 Choke coil connect
6 Skip
7 COMMON
8 Skip
9 Skip
10 N.C.
11 Skip
12 Input terminal Vi(311VDC)
Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating.
External Component Specifications
FUSE: Fuse
Use a fuse of...