Data Sheet
100VAC Input/−12VDC (300mA) Output
Non-Isolated AC/DC Converter
BP5061
Absolute Maximum Ratings
Parameter ...
Data Sheet
100VAC Input/−12VDC (300mA) Output
Non-Isolated AC/DC Converter
BP5061
Absolute Maximum Ratings
Parameter Input
voltage Output current ESD endurance Operating temperature range Storage temperature range
Symbol
Vi Io Vsurge Topr Tstg
Limits
−170 300
2 −25 to +80 −25 to +105
Unit
V mApk
kV °C °C
Electrical Characteristics
Parameter
Symbol Min.
Input
voltage range Output
voltage Output current
Vi −113 Vo −11.0 Io 0
Line regulation Load regulation Output ripple
voltage Power conversion efficiency
Vr Vl Vp
η
−
−
− 70
Typ.
−141 −12.0
− 0.04 0.05 0.07 78
Max.
−170 −13.0 300 0.15 0.15 0.15
−
Unit V V mA V V
Vp-p %
Conditions
DC (80 to 120VAC)
Vi=−141V, Io=200mA
Vi=−141V
∗1
Vi=−113V to −170V, Io=200mA
Vi=−141V, Io=0 to 200mA
Vi=−141V, Io=200mA ∗2 Vi=−141V, Io=300mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Spike noise is not included in output ripple
voltage.
Application Circuit
BP5061
Please note that pin No.12 side is input.
Input AC100V 50Hz/60Hz
12 10
D1
R1 10Ω1/4W
FUSE 1A
ZNR − C1
C2
220V + 33µF/200V 0.1µF
Pin No.
Function
1 Output terminal Vo(−12V)
2 Not used
3 Coil connect
4 Not used
5 Coil connect
6 Not used
7 COMMON
8 Not used
7 531
9 Not used 10 N.C.
11 Not used
Output 12 Input
voltage Vi(−141VDC)
L1 −12V
1mH − C3
+ 100µF/50V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage. Ensur...