Data Sheet
100VAC Input/−12VDC (500mA) Output
Non-Isolated AC/DC Converter
BP5062A
Absolute Maximum Ratings
Parameter...
Data Sheet
100VAC Input/−12VDC (500mA) Output
Non-Isolated AC/DC Converter
BP5062A
Absolute Maximum Ratings
Parameter Input
voltage Output current ESD endurance Operating temperature range Storage temperature range
Symbol Vi Io
Vsurge Topr Tstg
Limits −190 500
2 −20 to +80 −25 to +105
Unit V mA kV C C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input
voltage range
Vi −113 −141 −180 V DC (80 to 127VAC)
Output
voltage
Vo −11.0 −12.0 −13.0 V Vi= −141V, Io=300mA
Output current
Io 0 − 500 mA Vi= −141V
∗1
Line regulation
Vr − 0.05 0.15 V Vi= −113V to −170V, Io=300mA
Load regulation
Vl − 0.07 0.20 V Vi= −141V, Io=0 to 300mA
Output ripple
voltage Vp
− 0.05 0.15 Vp-p Vi= −141V, Io=300mA ∗2
Power conversion efficiency η 75 83 − % Vi= −141V, Io=500mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Spike noise is not included in output ripple
voltage.
Application Circuit
BP5062A
Please note that pin No.12 side is input.
Input AC100V 50Hz/60Hz
D1 ZNR −
220V+
12 10
R1 10 1/4W
FUSE 2A
87
C1 C2
47µF/200V 0.1µF
53
L1
470µH
Pin No.
Function
1 Output terminal Vo( −12V)
2 Not used
3 Coil connect
4 Not used
5 Coil connect
6 Not used
7 COMMON
8 COMMON
9 Not used
1 10 N.C.
11 Not used
Output
12 Input terminal Vi( −141VDC)
−12V
− C3 + 220µF/50V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage...