Data Sheet
100VAC Input/−5V (500mA) Output
Non-Isolated AC/DC Converter
BP5062A5
Absolute Maximum Ratings
Parameter I...
Data Sheet
100VAC Input/−5V (500mA) Output
Non-Isolated AC/DC Converter
BP5062A5
Absolute Maximum Ratings
Parameter Input
voltage Output current ESD endurance Operating temperature range Storage temperature range
Symbol Vi Io
Vsurge Topr Tstg
Limits −195 500
2 −20 to +80 −25 to +105
Unit V
mApk kV °C °C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input
voltage range
Vi −113 −141 −195 V DC (80 to 137VAC)
Output
voltage
Vo −4.7 −5.0 −5.3 V Vi=−141V, Io=500mA
Output current
Io 0 − 500 mA Vi=−141V
∗1
Line regulation
Vr
− 0.05 0.2
V Vi=−113V to −195V, Io=500mA
Load regulation
Vl
− 0.07 0.3
V Vi=−141V, Io=0 to 500mA
Output ripple
voltage Vp
− 0.15 0.3 Vp-p Vi=−141V, Io=500mA ∗2
Power conversion efficiency η 60 69 − % Vi=−141V, Io=500mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Spike noise is not included in output ripple
voltage.
Application Circuit
BP5062A5
Please note that pin No.12 side is input.
12 10
D1 1SR139-400
R1 4.7Ω1/4W
FUSE 2A
87
Input AC100V 50Hz/60Hz
ZNR − C1
C2
220V + 22µF/200V 0.22µF
53
L1 220µH
Pin No.
Function
1 Output terminal Vo(−5V)
2 Not used
3 Coil connect
4 Not used
5 Coil connect
6 Not used
7 COMMON
8 COMMON
9 Not used
1 10 N.C.
11 Not used
Output
12 Input terminal Vi(−141VDC)
−5V
− C3
+ 470µF/25V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actua...