Data Sheet
100VAC Input/−12VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5090-12
Absolute Maximum Ratings
Paramet...
Data Sheet
100VAC Input/−12VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5090-12
Absolute Maximum Ratings
Parameter Input
voltage Operating temperature range Storage temperature range Maximum surface temperature Output current
Symbol Vi
Topr Tstg Tsmax
Io
Limits −195 −20 to +85 −25 to +105 100
200
Unit V °C °C °C mA
Electrical Characteristics
Parameter
Symbol Min.
Input
voltage range
Vi −113
Output
voltage
Vo −11.5
Output current
Io −
Line regulation
Vr −
Load regulation
Vl −
Output ripple
voltage Vp
−
Conversion efficiency η
74
Typ. −141 −12.5
− 0.04 0.03 0.07 82
Max. −195 −13.2 200 0.20 0.20 0.20
−
Unit V V mA V V
Vp-p %
Conditions DC(80 to 138VAC)
Vi=−113 to −195V Io=0 to 200mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Spike noise is not included in output ripple
voltage.
∗1 ∗2
Application Circuit
BP5090-12
Please note that pin No.8 side is input.
Be sure to use fuse for safety. D1 R1
8 FUSE
5321
Pin No.
Function
1 Common
2 Output
3 Power inductor
4 Skip
5 Power inductor
6 Skip
7 Skip
8 Input
L1
-
Vi
ZNR
C1 C3
C2 +
Vo
Coil start
Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating.
External Component Specifications
FUSE: FUSE C1: Input capacitor
C2: Output capacitor
Use a fast-acting fuse of 1.0A.
Rated
voltage : More than 250V Capacitance : 22 to 100µF
Ra...