BR605 THRU BR610
SINGLE-PHASE SILICON BRIDGE Reverse Voltage - 50 to 1000 Volts Forward Current - 6.0 Amperes
Features
...
BR605 THRU BR610
SINGLE-PHASE SILICON BRIDGE Reverse
Voltage - 50 to 1000 Volts Forward Current - 6.0 Amperes
Features
Surge overload rating - 125 amperes peak Low forward
voltage drop Small size; simple installation Silver plated copper leads Mounting position: Any
DIM ENSIONS DIM A B C E F G inches Min. 0.580 0.230 0.405 0.750 0.038 Max. 0.620 0.270 0.445 0.042 Min. 14.69 5.84 10.29 19.1 0.97 mm Max. 15.71 6.86 11.31 1.07 Note
HOLE FOR NO. 6 SCREW
Maximum Ratings and Electrical Characteristics
Ratings at 25 ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
Symbols
BR605
BR61
BR62
BR64
BR66
BR68
BR610
Units
Maximum repetitive peak reverse
voltage Maximum RMS bridge input
voltage Maximum average forward rectified output current at TC=100 TA=50 * **
VRRM VRMS I(AV) IFSM VF TA=25 TA=100 IR TJ TSTG
50 35
100 70
200 140
400 280 6.0 6.0 125.0 1.0 10.0 1.0 -55 to +125 -55 to +150
600 420
800 560
1000 700
Volts Volts Amps Amps Volt uA mA
Peak forward surge current, 8.3mS single half sine-wave superimposed on rated load Maximum forward
Voltage drop per element at 3.0A peak Maximum DC reverse current at rated DC blocking
voltage per element Operating temperature range Storage temperature range
Notes: * Unit mounted on metal chassis ** Unit mounted on P.C. board
1
RATINGS AND CHARACTERISTIC CURVES
2
...