Additional Resources: Product Page | 3D Model | PCB Footprint
SERIES: CSXX05U │ DESCRIPTION: CURRENT SENSOR
FEATURES
• o...
Additional Resources: Product Page | 3D Model | PCB Footprint
SERIES: CSXX05U │ DESCRIPTION: CURRENT SENSOR
FEATURES
open loop unipolar detects current direction single channel
date 09/03/2019 page 1 of 4
MODEL
CS0305U
rated current (If) (ARMS) +3
linearity range1 (Im) (APEAK) +6
CS0505U
+5
+10
CS1005U
+10
+20
CS1505U
+15
+30
CS2005U
+20
+40
Notes: 1. Im is the maximum peak current for which the output
voltage specifications are guaranteed, however the If RMS rating must not be exceeded. 2. All specifications measured at 25°C, Rl=10 kΩ, unless otherwise noted. 3. It is recommended to add a 1 μF capacitor connected between the common terminal 4 and the +5 V terminal 1 to avoid noise problems.
SPECIFICATIONS
parameter supply
voltage (Vcc) max current consumption (Ic) output
voltage (Vo) zero current offset
voltage (Vr) output
voltage linearity4 (ΔKo) response (tr) output
voltage temperature characteristics zero current offset
voltage characteristics hysteresis (Vh)
conditions/description
at +If after demagnetization at di/dt = If/μs
at +If to zero current
min 4.75
2.26 0.27
typ 5.00
2.30 0.30
7
max 5.25 25 2.34 0.33 ±0.5
±0.1
±1.5 8
primary over current
for maximum 50 ms, no damage
withstand
voltage
between coil and each terminal for 1 minute
insulation resistance
between coil and each terminal at 500 Vdc
operating temperature
storage temperature
safety approvals
UL 508
flammability rating
UL94V-0
RoH...