SPECIFICATIONS:
Input
DCD models: 24 Vdc, 18-32 Vdc; DCG models: 48 Vdc, 36-72 Vdc.
Hold-up Time
6mSec minimum from loss of dc input at full load, nominal line.
power dissipation in some outputs. Consult factory for application assistance.
Efficiency
68% minimum at full rated load, nominal input
voltage, depending upon model and load distribution. Single-output models = 72% to 80% depending upon model.
Output Power
Normal continuous output power is 40 W (45 W Pk) for 60 sec.
Output Regulation
Regulation for multiple-output models measured by ±40% load changeFrom 60% rated load with all other outputs at 60% full rated load and a line
voltage change from low line to high line. Initial set tolerance is measured with all outputs at 60% of full rated load. Output
voltage V1 requires 20% load for proper regulation of multiple-output models. Regulation for single-output models measured by changing load from 5% load to 50% load or 50% load to full load in either direction.
Overshoot
Less than 3% at turn-on under nominal conditions, inversely proportional to input
voltage and temperature. Less than 2% overshoot at turn-off under all conditions.
Turn-on Time
Less than 1 sec. At nominal line,...