www.DataSheet4U.com Level Sensors Amplifier, Conductive Type ELC (Charging), ELD (Discharging) • • • • • Level control for conductive liquids Max./min. control of charging (ELC) or discharging (ELD) Adjustable sensitivity: 10 - 100 kΩ Output: 5 A SPDT For mounting on DIN-rail in accordance with DIN/EN 50 022 • 22.5 mm housing • LED-indication for relay and power supply ON • AC power supply Product Description Level control relay with max./min. control of charging or discharging. The sensitivit.

  ELDC024100K   ELDC024100K






(ELDC Type) Level Sensors Amplifier

www.DataSheet4U.com Level Sensors Amplifier, Conductive Type ELC (Charging), ELD (Discharging) • • • • • Level control for conductive liquids Max./min. control of charging (ELC) or discharging (ELD) Adjustable sensitivity: 10 - 100 kΩ Output: 5 A SPDT For mounting on DIN-rail in accordance with DIN/EN 50 022 • 22.5 mm housing • LED-indication for relay and power supply ON • AC power supply Product Description Level control relay with max./min. control of charging or discharging. The sensitivity is adjustable on absolute scale from 10 to 100 kΩ. When using only the max. level sensor, single level control is possible. Ordering Key Housing Function Type Output Power supply Measuring range ELC C 230 100K Type Selection Mounting For DIN-rail Output SPDT SPDT Type Charge (Filling) Discharge (Emptying) Supply: 24 VAC ELC C 024 100K ELD C 024 100K Supply: 115 VAC ELC C 115 100K ELD C 115 100K Supply: 230 VAC ELC C 230 100K ELD C 230 100K www.DataSheet4U.com Max. level Min. level 10 - 100 kΩ ≤3s ≤ 20 kΩ (typ. 5 kΩ) ≤ 25 VAC/250 µA (rms) Input Specifications Input through Y1 & Y2 through Y1 & Y3 Range Reaction time Repeat accuracy Sensor voltage Output Specifications Output Rated insulation voltage Contact ratings (AgCdO) Resistive loads AC 1 DC 1 Small inductive loads AC 15 DC 13 Mechanical life Electrical life Operating frequency SPDT relay 250 VAC (contact/elect.) 5 A/250 VAC 5 A/24 VDC 2 A/250 VAC 3 A/24 VDC ≥ 40 x 106 operations ≥ 105 operations (at max. load) ≤ 7200 opera.


2006-07-06 : XR205    XR-205    C3180    MB88516B    MB88515B    MB88514B    MB88517B    MB88518B    MB88PG517B    LS8204   


@ 2014 :: Datasheetspdf.com ::
Semiconductors datasheet search & download site (Privacy Policy & Contact)