Current Transducer HAR 1000-S
For the electronic measurement of currents: AC, DC, pulsed, mixed, with a galvanic isolati...
Current Transducer HAR 1000-S
For the electronic measurement of currents: AC, DC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = ± 1000A VOUT = ± 5V
Electrical data
IPN IP VC IC RIS VOUT ROUT Vb Vd RL Ve Primary nominal current Primary current, measuring range @ VC = ±15V Supply
voltage (± 5 %) Current consumption Isolation resistance @ 500 VDC Output
voltage @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance R.m.s. rated isolation
voltage R.m.s.
voltage for AC isolation test, 50/60Hz, 1mn Load resistance Partial discharge extinction
voltage @ ≤ 10 pC ±1000 ±2500 ±15 <±20 >500 ±5 <100 ≥2.1 ≥7 ≥10 ≥3.6 A A V mA MΩ V Ω kV kV kΩ kV
Features
Hall effect measuring principle Galvanic isolation between primary Isolation
voltage 7kV Wide measuring range (2.5 x IPN) UL 94-V0 rated
and secondary circuit
Advantages
Easy mounting Compact High immunity to external
interference
Accuracy-Dynamic performance data
ε
X
TCε G VOE VOH
L
VOT tr f
Accuracy @ IPN, TA = 25°C, VC = ±15V(±5 %) Linearity (0 .. ± IPN) Thermal drift of the gain (between -40 .. +70°C) Electrical offset
voltage, TA = 25°C Hysteresis offset
voltage @ IP = 0; after an excursion of 1 x IPN Thermal drift of offset (between -40 .. +70°C) Response time @ 90% of IP Frequency bandwidth (-3 dB)
2)
<±0.5 <±0.5 ≤±5.5 <±20
% of IPN % of IPN % of IPN mV mV mV µs kHz
Low power consumption
Applications
Tracti...