Current Transducer HNC- 050 .. 100P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic i...
Current Transducer HNC- 050 .. 100P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 50 .. 100 A
Electrical data
Primary nominal DC current Primary current measuring range Type
IPN (A)
50 100
IP (A)
0 .. ± 75 0 .. ± 140 HNC - 050P HNC - 100P HNC - 050P HNC - 100P
RM ISN KN VC IC Vd
Measuing resistance Second nominal current Turns ratio
60 .. 90 50 1 : 1000
60 .. 80 50 1 : 2000
Ω mA V mA kV
Features
Hall effect measuring principle Galvanic isolation between primary Isolation
voltage 2500 V Low power consumption
and secondary circuit
Supply
voltage (± 5 %) ± 15 Current consumpution 15 + ISN R.m.s.
voltage for AC isolation test, 50/60Hz, 1 min 2.5
Accuracy-Dynamic performance data
Advantages
± 1 % of IPN < ± 0.5 % ± 0.2 mA ± 0.15 mA ± 0.005 ms/°C <1 µs < ± 0.004 %/°C
ε
X
L
IO IHC IOT tr TCε G
Accuracy @ T A = 25°C Linearity (0 .. ± IPN ) Electrical offset current @IP = 0, @T A = 25°C Hysteresis offset current @ IP = 0, after an excursion of IPN Thermal drift of IO 0°C .. +70°C Response time @ 90% of IP Thermal drift of the gain (% of reading)
Easy mounting Small size and space saving Only one design for wide current High immunity to external interference
ratings range
Applications
DC motor drives Switched Mode Power Supplies
General data
TA TS RS m Ambient operating temperature Ambient storage temperat...