Receivers. IN1489A Datasheet

IN1489A Datasheet PDF

Part IN1489A
Description Qudruple Line Receivers
Feature Qudruple Line Receivers TECHNICAL DATA IN1489A The IN1489A is a monolithic quadruple line receiver.
Manufacture Integral
Datasheet
Download IN1489A Datasheet

w between this terminal and ground to shift the input thresh IN1489A Datasheet
Qudruple Line Receivers TECHNICAL DATA IN1489A The IN1489A IN1489A Datasheet




IN1489A
Qudruple Line Receivers
TECHNICAL DATA
IN1489A
The IN1489A is a monolithic quadruple line receivers designed to
satisfy the requirements of the standard interface between data terminal
equipment and data communication equipments as defined by EIA
standard RS-232C. A separate response control terminal is provided
for each receiver. A resistor or a resistor and bias voltage can be
connected between this terminal and ground to shift the input threshold
voltage levels. An external capacitor can be connected from this
terminal to ground to provide input noise filtering.
Input Resistance ... 3 kto 7k
Input Signal Range ... ±30 V
Operates from Single 5 V Supply
Built-IN Input Hysteresis (Double Thresholds)
Response Control Provides: Input Tresold
Shifting
Input Noise Filtering
Satisfies Requirements of EIA RS-232C
ORDERING INFORMATION
IN1489AN Plastic
IN1489AD SOIC
TA = -10° to 70° C
for all packages
LOGIC DIAGRAM
PIN ASSIGNMENT
PIN 14 =VCC
PIN 7 = GND
FUNCTION TABLE
Inputs
A
L
H
Output
Y
H
L
1



IN1489A
IN1489A
MAXIMUM RATINGS*
Symbol
VCC
VIN
IO
Tstg
Parameter
Supply Voltage
Input Voltage
Output Current
Storage Temperature Range
Value
6
±25
10
-65 to +150
*Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
Unit
V
V
mA
°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VCC Supply Voltage
VIH High Level Input Voltage
VIL Low Level Input Voltage
IOL Low Level Output Current
TA Ambient Temperature Range
Min Max Unit
5.5 V
25 V
-25 V
10 mA
-10 +70 °C
DC ELECTRICAL CHARACTERISTICS over full operating conditions
Symbol
VT+
VT-
VOH
Parameter
Positive-Going Tthreshold
Input Voltage
Negaitive-Going Tthreshold
Voltage
High-Level Output Voltage
VOL High-Level Output Voltage
IIH High Level Input Current
IIL Low Level Input Current
IOS Short Circuit Output Current
ICC Supply Current
Test Conditions
VI= 0.75 V, IOL = -0.5 mA
Input open, IOH=-0.5 mA
VI= 3 V, IOL = 10 mA
VI=25 V
VI=3 V
VI=-25 V
VI=-3 V
VI=5 V, Outputs open
Guaranteed Limit
Min Max
1.75 2.25
0.75 1.25
2.6
2.6
3.6
0.43
-3.6
-0.43
0.45
8.3
-8.3
-4.0
26
Unit
V
V
V
V
mA
mA
mA
mA
2




@ 2014 :: Datasheetspdf.com ::