DatasheetsPDF.com

JCK2024D12 Datasheet

Part Number JCK2024D12
Manufacturers XP Power
Logo XP Power
Description DC-DC Converter
Datasheet JCK2024D12 DatasheetJCK2024D12 Datasheet (PDF)

DC DC 20 Watts JCK Series xppower.com • 2:1 Input Range • 40 °C to +100 °C Operating Temperature • Single & Dual Outputs • Remote On/Off • High Efficiency up to 93% • 1600 VDC Isolation • 3 Year Warranty Specification Input Input Voltage Range Input Current Undervoltage Lockout Input Surge • 12 V (9-18 VDC) 24 V (18-36 VDC) 48 V (36-75 VDC) • See table • 12 V models: ON 8.6 V, OFF 7.9 V typical 24 V models: ON 17.8 V, OFF 16 V typical 48 V models: ON 33.5 V, OFF 30.5 V typical • 12 V model.

  JCK2024D12   JCK2024D12






Part Number JCK2024D15
Manufacturers XP Power
Logo XP Power
Description DC-DC Converter
Datasheet JCK2024D12 DatasheetJCK2024D15 Datasheet (PDF)

DC DC 20 Watts JCK Series xppower.com • 2:1 Input Range • 40 °C to +100 °C Operating Temperature • Single & Dual Outputs • Remote On/Off • High Efficiency up to 93% • 1600 VDC Isolation • 3 Year Warranty Specification Input Input Voltage Range Input Current Undervoltage Lockout Input Surge • 12 V (9-18 VDC) 24 V (18-36 VDC) 48 V (36-75 VDC) • See table • 12 V models: ON 8.6 V, OFF 7.9 V typical 24 V models: ON 17.8 V, OFF 16 V typical 48 V models: ON 33.5 V, OFF 30.5 V typical • 12 V model.

  JCK2024D12   JCK2024D12







DC-DC Converter

DC DC 20 Watts JCK Series xppower.com • 2:1 Input Range • 40 °C to +100 °C Operating Temperature • Single & Dual Outputs • Remote On/Off • High Efficiency up to 93% • 1600 VDC Isolation • 3 Year Warranty Specification Input Input Voltage Range Input Current Undervoltage Lockout Input Surge • 12 V (9-18 VDC) 24 V (18-36 VDC) 48 V (36-75 VDC) • See table • 12 V models: ON 8.6 V, OFF 7.9 V typical 24 V models: ON 17.8 V, OFF 16 V typical 48 V models: ON 33.5 V, OFF 30.5 V typical • 12 V models 36 VDC for 100 ms 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms Output Output Voltage • See table Output Voltage Trim • ±10% max on single outputs Minimum Load • No minimum load required Line Regulation • ±0.5% max Load Regulation • Single output models: ±0.5% max Dual output models: ±1% max balanced outputs Cross Regulation • ±5% for dual outputs (see note 2) Setpoint Accuracy • ±1% max Start Up Delay • <20 ms Start Up Rise Time • <5 ms Ripple & Noise • 75 mV pk-pk (see note 3) Transient Response • ±3% max deviation, recovery to within 1% in 250 µs for a 25% load change Temperature Coefficient • 0.02%/°C Overvoltage Protection • 3.3 V models: 3.9 V typical 5 V models: 6.2 V typical 12 V models: 15 V typical 15 V models: 18 V typical ±12 V models: ±15 V typical ±15 V models: ±18 V typical Overload Protection • >140% of full load at nominal input Short Circuit Protection • Trip & restart (hiccup mode), auto recovery Remote On/Off • On = Logi.


2019-12-24 : JTE0648D15    JTE0648D24    JTE0648D12    JTE0648D05    JTE0648S24    JTE0648D03    JTE0648S15    JTE0648S12    JTE0648S3V3    JTE0648S05   


@ 2014 :: Datasheetspdf.com ::
Semiconductors datasheet search & download site (Privacy Policy & Contact)