LAL0660-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation...
LAL0660-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and 250V working
voltage RoHS Compliant Excellent THD performance Operating Temperature -40°C to 85°C
OCL: Leakage Inductance: IInterwinding Capacitance
T.H.D
D.C.R Hi-POT : Turn Ratio:
Electrical Specifications @25℃
PIN 16-9= 700uH ±6% @ 10KHz/0.1V/Ser.
PIN 1-4= 1.2uH ±0.2 @ 100KHz/0.1V
PIN 5-8= 4.0uH ±1.0
PIN 16-9= 15uH ±2.0
PIN 1-16= 20 pF ±5.0 @ 100KHz/0.1V PIN 5-16= 20 pF ±5.0 PIN 1-8= 15 pF ±3.0
PIN 1-4 to PIN 9-16= -90dB Max. @ 100KHz/7.5V
PIN 5-8 to PIN 9-16= -90dB Max. @ 100KHz/7.5V
PIN 1-4 = 1.15 ohm ±15%
PIN 5-8 = 2.0 ohm ±15%
PIN 16-9 = 4.1 ohm ±15%
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA PIN16-9 : PIN 1-4 = 4±3% :1
PIN16-9 : PIN 5-8 = 2±3% :1
15.14±0.5 2.5
11.4 16.6
Dimensions (Units: mm)
F 5.1±0.3
3.4±0.3 G
LAL****
LinkCom
X DATE CODE G
B
1.00
13.5±0.5 A
PIN1
11.90 SUGGESTED PADS LAYOUT
12.5±0.5
C