Embedded Power for Business-Critical Continuity
SXX06E
Rev. 08.01.06
Page 1 of 2
LDO10C Series
50 Watts
Total Power:...
Embedded Power for Business-Critical Continuity
SXX06E
Rev. 08.01.06
Page 1 of 2
LDO10C Series
50 Watts
Total Power: 50 Watts Input
Voltage: 3-13.8 Vdc No. of Outputs: Single
Rev. 09.03.08 LDO10C 1 of 4
Electrical Specifications
Output
Output
voltage Output setpoint accuracy Line regulation Load regulation Min./max. load Overshoot Undershoot Ripple and noise 5 Hz to 20 MHz Transient response At turn-on At turn-off See Note 1 See Notes 1, 2 See Note 5 0.1% trim resistors Low line to high line Full load to min. load 0.59-5.1 V ±1.0% ±0.2% ±0.5% 0 A/10 A 0.5% max. 100 mV max. 20 mV Vin=5 V, Vout=2.5 V 130 mV max. deviation 15 μs recovery to within regulation band 3-13.8 Vdc Minimum load Remote OFF See Note 3 Power up Remote ON/OFF Vin=5 V, Vo=2.5 V, lo=10 A Fixed 50 mA 5 mA 10 A @ lo max. 3 ms 2 ms 91% 620 kHz UL94V-0 1.899 g (0.067 oz.) 12 V @ 40 °C, 100% load Bellcore 332 Surface mount models 8,220,210 hours 150μm
Special Features
10 A output current rating Input
voltage range: 3-13.8 Vdc Adjustable out
voltage: 0.59-5.1 V Factory set with power good option Excellent transient response Power enable Minimum airflow Small package Termination
voltage capability RoHS compliant
Input
Input
voltage range Input current Input current (max.) Start-up time
General
Efficiency Switching frequency Material flammability Weight MTBF Coplanarity
Safety
UL, cUL 60950-1 TÜV Product Service (EN60950) Certificate No. TBD CB Report and Certificate to IEC60950
Embedde...