DatasheetsPDF.com

LPS113 Datasheet

Part Number LPS113
Manufacturers Emerson
Logo Emerson
Description AC-DC / 86W - 135W
Datasheet LPS113 DatasheetLPS113 Datasheet (PDF)

110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM fo.

  LPS113   LPS113






Part Number LPS118-B
Manufacturers Emerson
Logo Emerson
Description AC-DC / 86W - 135W
Datasheet LPS113 DatasheetLPS118-B Datasheet (PDF)

110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM fo.

  LPS113   LPS113







Part Number LPS118
Manufacturers Emerson
Logo Emerson
Description AC-DC / 86W - 135W
Datasheet LPS113 DatasheetLPS118 Datasheet (PDF)

110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM fo.

  LPS113   LPS113







Part Number LPS115-B
Manufacturers Emerson
Logo Emerson
Description AC-DC / 86W - 135W
Datasheet LPS113 DatasheetLPS115-B Datasheet (PDF)

110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM fo.

  LPS113   LPS113







Part Number LPS115
Manufacturers Emerson
Logo Emerson
Description AC-DC / 86W - 135W
Datasheet LPS113 DatasheetLPS115 Datasheet (PDF)

110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM fo.

  LPS113   LPS113







Part Number LPS114-B
Manufacturers Emerson
Logo Emerson
Description AC-DC / 86W - 135W
Datasheet LPS113 DatasheetLPS114-B Datasheet (PDF)

110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM fo.

  LPS113   LPS113







AC-DC / 86W - 135W

110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM forced air ±5% minimum 20 ms @80 W load, 115 VAC nominal line Short circuit protection. Case overload protected @ 110-145% above peak rating 5 V output: 5.7-6.7 VDC. Other outputs 10% to 20% above nominal output. Latching type, recycle AC to reset. TTL logic signal goes high 50-150 msec after main output. It goes low at least 4 msec before loss of regulation. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Input current Efficiency EMI filter Special Features • • • • • • • • • • • Universal input High efficiency Remote sense Built-in EMI filter Low output ripple Adjustable output Power fail Overvoltage protection Overload protection Optional L bracket (-B suffix) Cover kit available LPX110-C Safety ground leakage current Output Maximum power Adjustment range Hold-up time Overload protection Overvoltage protection Environmental Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70.


2009-10-25 : AEH25B48    AEH25B48-6    AEH25B48-6CL    AEH25B48-CL    AEH25B48N    AEH25B48N-6    AEH25B48N-6    AEH25B48N-6CL    AEH25B48N-CL    AEH25B48N-L   


@ 2014 :: Datasheetspdf.com ::
Semiconductors datasheet search & download site (Privacy Policy & Contact)