www.DataSheet.co.kr
E2V Technologies MG5424 X-Band Magnetron
The data should be read in conjunction with the Magnetron...
www.DataSheet.co.kr
E2V Technologies MG5424 X-Band Magnetron
The data should be read in conjunction with the Magnetron Preamble.
MAXIMUM AND MINIMUM RATINGS
(Absolute values)
These ratings cannot necessarily be used simultaneously, and no individual rating should be exceeded. Min Max Heater
voltage (see note 1) . . . . . 5.7 6.9 V Heater starting current (peak) . . . . – 3.0 A Anode
voltage (peak) . . . . . . . – 8.6 kV Anode current (peak) . . . . . . . 5.0 10 A Input power (mean) (see note 5) . . . – 100 W Pulse duration . . . . . . . . . – 2.0 ms Rate of rise of
voltage pulse (see notes 6 and 7) . . . . . . . – 150 kV/ms VSWR at the output coupler . . . . – 1.5:1 Anode temperature . . . . . . . – 120 8C
DESCRIPTION
Compact, rugged, lightweight, fixed frequency magnetron, electrically the same as M5187. pulse
GENERAL DATA
Electrical
Operating frequency . . . . . Typical peak output power . . . . Cathode . . . . . . . . . . Heater
voltage (see note 1) . . . . Heater current at 6.3 V (see note 2) . Cathode pre-heating time (minimum) (see note 3) . . . . . . . . Input capacitance . . . . . . . Temperature coefficient of frequency 9410 + 30 MHz . . 25 kW . . indirectly heated . . . 6.3 V . . . 0.5 A . . 60 s . . . 9.0 pF max . . . . see note 4
TYPICAL OPERATION
Operating Conditions
Heater
voltage (for operation) Anode current (peak) . . . Pulse duration . . . . . Pulse repetition rate . . . Rate of rise of
voltage pulse . . . . . . . . . . . . . . . . . . . . . . . 6.3 . ...