SENSOR. MQ6 Datasheet

MQ6 Datasheet PDF


MQ6
HANWEI SENSORS
MQ-6
www.hwsensor.com
TECHNICAL DATA
MQ-6 GAS SENSOR
FEATURES
* High sensitivity to LPG, iso-butane, propane
* Small sensitivity to alcohol, smoke.
* Fast response . * Stable and long life * Simple drive circuit
APPLICATION
They are used in gas leakage detecting equipments in family and industry, are suitable for detecting of
LPG, iso-butane, propane, LNG, avoid the noise of alcohol and cooking fumes and cigarette smoke.
SPECIFICATIONS
A. Standard work condition
Symbol
Parameter name
Vc Circuit voltage
VH Heating voltage
PL Load resistance
RH Heater resistance
PH Heating consumption
B. Environment condition
Technical condition
5V±0.1
5V±0.1
20KΩ
33Ω±5%
less than 750mw
Remarks
AC OR DC
ACOR DC
Room Tem
Symbol
Tao
Tas
Parameter name
Using Tem
Storage Tem
Technical condition
-10-50
-20-70
Remarks
RH Related humidity
less than 95%Rh
O2
Oxygen concentration
21%(standard condition)Oxygen
minimum value is
concentration can affect sensitivity over 2%
C. Sensitivity characteristic
Symbol
Rs
α
(1000ppm/
4000ppm LPG)
Standard
detecting
condition
Parameter name
Sensing Resistance
Technical parameter
10KΩ- 60KΩ
(1000ppm LPG )
Concentration slope rate
0.6
Temp: 20℃±2Vc:5V±0.1
Humidity: 65%±5% Vh: 5V±0.1
Remarks
Detecting concentration
scope
200-10000ppm
LPG , iso-butane,
propane,
LNG
Preheat time
Over 24 hour
D. Strucyure and configuration, basic measuring circuit
Parts
1 Gas sensing
layer
2 Electrode
3 Electrode line
4 Heater coil
5 Tubular ceramic
6 Anti-explosion
network
7 Clamp ring
8 Resin base
9 Tube Pin
Materials
SnO2
Au
Pt
Ni-Cr alloy
Al2O3
Stainless steel gauze
(SUS316 100-mesh)
Copper plating Ni
Bakelite
Copper plating Ni
Configuration A
Fig. 1
Configuration B
Fig.2
TEL:86-371-67169080
FAX: 86-A371-67169090
E-mail:sales@Ahwsensor.com


Part MQ6
Description GAS SENSOR
Feature MQ6; HANWEI SENSORS MQ-6 www.hwsensor.com TECHNICAL DATA MQ-6 GAS SENSOR www.DataSheet4U.com FEATU.
Manufacture HANWEI
Datasheet
Download MQ6 Datasheet

MQ-6 Semiconductor Sensor for LPG Sensitive material of MQ-6 MQ6 Datasheet
HANWEI SENSORS MQ-6 www.hwsensor.com TECHNICAL DATA MQ- MQ6 Datasheet
www.DataSheet4U.com www.DataSheet4U.com MQ6001 Datasheet
MQ6002 Datasheet
MQ6002HXV Datasheet
DC AXIAL FANS Rotation 8- 0.17 ±0.01 (8- Ø4.4 ±0.3) STATIC MQ6038E Datasheet
DC AXIAL FANS Rotation 8- 0.17 ±0.01 (8- Ø4.4 ±0.3) STATIC MQ6038H Datasheet
DC AXIAL FANS Rotation 8- 0.17 ±0.01 (8- Ø4.4 ±0.3) STATIC MQ6038L Datasheet
DC AXIAL FANS Rotation 8- 0.17 ±0.01 (8- Ø4.4 ±0.3) STATIC MQ6038M Datasheet





MQ6
HANWEI SENSORS
MQ-6
www.hwsensor.com
Structure and configuration of MQ-6 gas sensor is shown as Fig. 1 (Configuration A or B), sensor composed by
micro AL2O3 ceramic tube, Tin Dioxide (SnO2) sensitive layer, measuring electrode and heater are fixed into a
crust made by plastic and stainless steel net. The heater provides necessary work conditions for work of
sensitive components. The enveloped MQ-6 have 6 pin ,4 of them are used to fetch signals, and other 2 are used
for providing heating current.
Electric parameter measurement circuit is shown as Fig.2
E. Sensitivity characteristic curve
Fig.2 sensitivity characteristics of the MQ-6
10 MQ-6
1
Fig.3 is shows the typical
sensitivity characteristics of
the MQ-6 for several gases.
in their: Temp: 20℃、
Humidity: 65%
O2 concentration 21%
RL=20kΩ
Ro: sensor resistance at 1000ppm of
LPG in the clean air.
Rs:sensor resistance at various
concentrations of gases.
0.1
100
LPG
H2
CH4
CO
Alcohol
Air
1000
ppm
10000
1.4
1.3
1.2
1.1
1
0.9
0.8
0.7
0.6
0.5
-10 0
MQ-6
Fig.4
33%RH
85%RH
Fig.4 is shows the typical dependence of
the MQ-6 on temperature and humidity.
Ro: sensor resistance at 1000ppm of LPG in air
at 33%RH and 20 degree.
Rs: sensor resistance at 1000ppm of LPG in air
at different temperatures and humidities.
10 20 30 40 50
Temp
SENSITVITY ADJUSTMENT
Resistance value of MQ-6 is difference to various kinds and various concentration gases. So, When using
this components, sensitivity adjustment is very necessary. we recommend that you calibrate the detector for
1000ppm of LPG concentration in air and use value of Load resistance ( RL) about 20KΩ(10KΩ to 47KΩ).
When accurately measuring, the proper alarm point for the gas detector should be determined after
considering the temperature and humidity influence.
TEL:86-371-67169080
FAX: 86-371-67169090
E-mail:sales@hwsensor.com






@ 2014 :: Datasheetspdf.com ::
Semiconductors datasheet search & download site (Privacy Policy & Contact)