OC 48 & OC 192 PHASE SHIFTER FOR CLOCK & DATA RECOVERY 6705 K
SPECIFICATION BULLETIN
OC 48 & OC 192 PHASE SHIFTER FOR CLOCK & DATA RECOVERY 6705 K
FEATURES • • • • • Small package s...
Description
SPECIFICATION BULLETIN
OC 48 & OC 192 PHASE SHIFTER FOR CLOCK & DATA RECOVERY 6705 K
FEATURES Small package size Trough line design Long life Available adjustment options Useable for OC48 & OC192
BROADBAND PHASE SHIFTER
ELECTRICAL SPECIFICATIONS
Frequency range (GHz) Phase shift, min (°/GHz) Phase shift nom (°/GHz/Shaft turn) Insertion phase, nom at min phase setting (°/GHz) Number of turns, min VSWR,max DC to 18GHz 18 to 26.5 GHz Insertion loss, max (db) DC to 18 GHz 18 to 26.5 GHz Average power handling (watts) Peak power handling (watts) Time delay range nom(nsec) DC-26.5 40 1.5 130 26 1.60 2.00 1.25 1.75 100 1000 0.4-0.5
MECHANICAL SPECIFICATIONS Length (inches) Width (inches) Height (inches) Weight (ounces) Connectors
3.83 1.5 0.38 3.75 Type K
NOTES: Useful for adjusting clock phase Assists in phase variation for digital data control Additional OC48 & OC192 components available Custom requests welcomed Visit Sage on-line at http/www.sagelabs.com to view full product and technology abilities
A Filtronic plc Company
PHONE: (508) 653-0844
FAX: (508) 653-5671