Specifications
Model
Nominal Output
Voltage
VDC 3.3V
5V
12V 15V 24V 28V
48V
Input
Voltage Range
VDC
200 - 425VDC
Input Current
A
See model selector
Output
Voltage Adjustment VDC
See model selector
Ripple & Noise (max) pk-pk mV
100
100
150
150
240 280 400 (300W: 480mV)
Line Regulation (max)
mV 10
10
24
30
48 56
96
Load Regulation (max)
mV 10
10
24
30
48 56
96
Overcurrent Protection
%
102 - 150% (Constant current style)
Over
voltage Protection (1) % 130 - 200 125 - 150 (1)
50-150W: 115 - 145%, 300W: 125 - 145%
Remote Sense
-
Yes
Remote On/Off
-
Yes; Low = ON, Open = OFF
Operating Temperature
oC
-40oC to +100oC Base-plate, -40oC to +85oC Ambient
Storage Temperature
oC
-40oC to +100oC
Temperature Coefficient
%/oC
0.02%/oC
Humidity (non condensing) %RH
5 - 95% RH Operating and Non Operating
Cooling
- Conduction (See Installation Manual for heatsink selection)
Withstand
Voltage
VAC
Input to Base-plate: 2.5kVAC; Input to Output 3.0kVAC for I min.;
Output to Base-plate: 500VAC for 1 min
Isolation Resistance
MΩ
>100MΩ at 25C and 70%RH, Output to Base plate 500VDC
Vibration
-
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant...