General Purpose Low Power PCB Relays
Power PCB Relay RT1 sensitive
n 1 pole 10A, 1 form C (CO) or 1 form A (NO) contact n Highly sensitive version, coil power 250mW n 5kV/10mm coil-contact n Reinforced insulation n Ambient temperature 85°C
SCHRACK
Typical applications Domestic appliances, heating control.
Z b
Approvals
VDE Cert. No. 40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact Data
Contact arrangement 1 form C (CO) or 1 form A (NO)
R.
General Purpose Low Power PCB Relays
General Purpose Low Power PCB Relays
Power PCB Relay RT1 sensitive
n 1 pole 10A, 1 form C (CO) or 1 form A (NO) contact n Highly sensitive version, coil power 250mW n 5kV/10mm coil-contact n Reinforced insulation n Ambient temperature 85°C
SCHRACK
Typical applications Domestic appliances, heating control.
Z b
Approvals
VDE Cert. No. 40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact Data
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400 VAC
Rated current
10A
Limiting making current; max. 4s, duty factor 10% 15A
Breaking capacity
2500VA
Contact material
AgNi 90/10
Frequency of operation; with/without load 3000/72000h-1
Operate/release time max.
10/8ms
Bounce time max.; form A/form B
4/9ms
Contact ratings
Type Contact Load
Cycles
IEC 61810
RT174 A/B (NO/NC) 10A, 250VAC resistive, 85°C
100x103
UL 508
RT174 C (CO)
10A, 250VAC, general purpose, 85°C 6x103
RT174 A/B (NO/NC) 10A, 250VAC, general purpose, 40°C 30x103
RT174 A/B (NO/NC) B300, 40°C
6x103
RT174 A (NO)
R150, 40°C
6x103
RT174 B (NC)
1/2hp, 240VAC, 40°C
1x103
RT174 A (NO)
3/4hp, 240VAC, 40°C
1x103
EN60730-1
RT174 A (NO)
6(4)A, 250VAC, 85°C
100x103
Mechanical endurance
>30x106 operations
Coil Data
Coil voltage range Operative range, IEC 61810 Coil insulation system according UL
5 to 60VDC 2
class F
.