AC-DC
150 Watts
www.DataSheet4U.com
xppower.com
SDS150 Series
• • • • • • • 3” x 5” Footprint Fits 1U Applications Co...
AC-DC
150 Watts
www.DataSheet4U.com
xppower.com
SDS150 Series
3” x 5” Footprint Fits 1U Applications Convection-cooled Open Frame & U-Channel Versions Optional Power Fail Detect Signal Optional Low Temperature Operation Up to 90% Efficiency
Specification
Input
Input
Voltage Input Frequency Input Current 90-264 VAC (120-370 VDC) 47-63 Hz 2.0 A at 115 VAC 1.0 A at 230 VAC Inrush Current 20 A at 115 VAC 63 A at 230 VAC Power Factor >0.95 Earth Leakage Current <0.40 mA at 115 VAC <0.75 mA at 230 VAC Input Protection 3.15 A on board fuse
General
Efficiency Isolation 88% typical, 90% max 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground PWM 60 kHz typical, PFC 100 kHz typical 6.9 W/In3 for open frame version Power Fail Detect = TTL low (option) >100 kHrs per MIL-HDBK-217F
Switching Frequency Power Density Signals MTBF
Environmental
Operating Temperature 0 °C to +70 °C, derate linearly from 100% load at +50 °C to 50% load at +70 °C, low temperature option ‘-L’ -40 °C Cooling Convection-cooled Operating Humidity 5-95% RH, non-condensing Storage Temperature -40 °C to +85 °C Vibration 2 g on 3 axes
Output
Output
Voltage Output
Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response Ripple & Noise Over
voltage Protection Overload Protection Short Circuit Protection Temperature Coefficient ...