SONGLE RELAY
www.datasheet4u.com
RELAY ISO9002
SLA
1. MAIN FEATURES
ᄋ Up to 30A switching in SPST and 20A switching i...
SONGLE RELAY
www.datasheet4u.com
RELAY ISO9002
SLA
1. MAIN FEATURES
ᄋ Up to 30A switching in SPST and 20A switching in spot arrangements. ᄋ Available as an open-frame relay, with a snap-on dust cover or with an immersion cleanable, plastic sealed case.
2. APPLICATIONS
ᄋ Used for power switching, Electrical Heater, ventilator, Air conditioning, Refrigerating, Automobile and House-hold Appliance.
3. ORDERING INFORMATION
SLA Model of relay SLA XX VDC Nominal coil
voltage 05 06 09 12 18 24 48 110VDC S Structure S:Sealed type Coil L sensitivity C Contact form A:1 form A B:1 form B C:1 form C
L:0.93W D:Special
F:Flux free type
4. RATING
20A/28VDC 250VAC 30A/30VDC 250VAC CCC FILE NUMBER:CQC03001003728 UL/CUL FILE NUMBER: E179944 TUV FILE NUMBER: R50056114 30A/250VDC NO:20A/240VAC 28VDC NC:10A/240VAC 28VDC NO:30A/250VAC 30VDC NC:20A/250VAC 30VDC
5. DIMENSION(unit:mm)
DRILLING(unit:mm)
WIRING DIAGRAM
1
6. COIL DATA CHART (AT20 ö C)
Coil Sensitivity
www.datasheet4u.com
SLA
Coil
Voltage Code 05 06 09 12 15 18 24 48 110
Nominal
Voltage (VDC) 5 6 9 12 15 18 24 48 110
Nominal Current (mA) 185 150 93 77 59 47 36 20 9
Coil Power Resistance Consumption (W) ( Ω) ᄋ10% 27 40 97 155 abt. 0.93W 256 380 660 2480 13000
Pull-In
Voltage (VDC)
Drop-Out
Voltage (VDC)
Max-Allowable
Voltage (VDC)
75% Max.
10% Max.
120%Max.
7. CONTACT RATING
Type Item Resistive Load (cosΦ=1) General Motor Ballast LRA/FLA FORM A 30A 250VAC 30A 30VDC 250VAC 2HP 120VAC 1HP FORM B SLA FORM C N/O N/C 20...