SM6T
Datasheet
600 W TVS in SMB
Features
• Peak pulse power: 600 W (10/1000 μs) and 4 kW (8/20 μs)
• Stand-off voltag...
SM6T
Datasheet
600 W TVS in SMB
Features
Peak pulse power: 600 W (10/1000 μs) and 4 kW (8/20 μs)
Stand-off
voltage range from 5 V to 188 V
Unidirectional and bidirectional types
Low leakage current: 0.2 μA at 25 °C and 1 μA at 85 °C
Operating Tj max: 150 °C
High power capability at Tj max.: up to 515 W (10/1000 µs)
K
Lead finishing: matte tin plating
Bidirectional
A Unidirectional
Product status link
SM6T
SM6T6V8A, SM6T6V8CA, SM6T7V5A, SM6T7V5CA,
SM6T10A, SM6T10CA, SM6T12A, SM6T12CA, SM6T15A, SM6T15CA, SM6T18A, SM6T18CA, SM6T22A, SM6T22CA, SM6T24A, SM6T24CA, SM6T27A, SM6T27CA, SM6T30A, SM6T30CA, SM6T33A, SM6T33CA, SM6T36A, SM6T36CA, SM6T39A, SM6T39CA, SM6T56A, SM6T56CA, SM6T68A, SM6T68CA, SM6T75A, SM6T75CA, SM6T100A, SM6T100CA, SM6T150A, SM6T150CA, SM6T200A, SM6T200CA, SM6T220A, SM6T220CA
Complies with the following standards
UL94, V0 J-STD-020 MSL level 1 J-STD-002, JESD 22-B102 E3 and MIL-STD-750, method 2026 solderable
matte tin plated leads JESD-201 class 2 whisker test IPC7531 footprint JEDEC registered package outline IEC 61000-4-4 level 4:
– 4 kV IEC 61000-4-2, C = 150 pF - R = 330 Ω exceeds level 4:
– 30 kV (air discharge) – 30 kV (contact discharge)
Description
The SM6T series are designed to protect sensitive equipment against electrostatic discharges according to IEC 61000-4-2 and MIL STD 883, method 3015, and electrical overstress according to IEC 61000-4-4 and 5. This device is more generally used against surges below ...