www.DataSheet4U.com
12,500 V - 25,000 V Rectifier Stacks
0.5 A Forward Current 150 ns Recovery Time
SP125F SP150F SP20...
www.DataSheet4U.com
12,500 V - 25,000 V Rectifier Stacks
0.5 A Forward Current 150 ns Recovery Time
SP125F SP150F SP200F SP250F
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number Working Reverse
Voltage (Vrwm) Average Rectified Current (in oil) (Io) 55°C Volts SP125F SP150F SP200F SP250F Amps 100°C Amps Reverse Current @ Vrwm (Ir) 25°C µA 100°C µA 25°C Volts Amps Forward
Voltage 1 Cycle Surge Current tp=8.3ms (Ifsm) 25°C Amps Repetitive Surge Current (Ifrm) 25°C Amps Reverse Recovery Time (1) (Trr) 25°C ns in. Case Length (L)
(Vf)
12500 15000 20000 25000
0.5 0.5 0.5 0.5
0.33 0.33 0.33 0.33
1.0 1.0 1.0 1.0
25 25 25 25
24.0 24.0 32.0 40.0
1.0 1.0 1.0 1.0
40 40 40 40
8 8 8 8
150 150 150 150
4.250 4.250 4.250 4.250
8
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp.= -55°C to +150°C Stg. Temp.= -55°C to +150°C
2.00(50.80) MIN.
.500 ±.020 (12.70 ±.50)
L ±.020
0.51 ±.003 (1.30 ±.08)
.250 ±.020 (6.35 ±.50)
Dimensions: In. (mm) All temperatures are ambient unless otherwise noted. Data subject to change without notice.
VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291
TEL 559-651-1402 FAX 559-651-0740 www.
voltagemultipliers.com
185
SP125F SP150F SP200F SP250F
0.6 0.5 Maximum Current (I) 0.4 0.3 0.2 0.1 0 25 50 75 100 125 Ambient Temperature Temperature (°C) (C) 150 Forward
Voltage (V)
MAXIMUM FORWARD CURRENT VS. TEMPERATURE
50 45 40 35 30 25 20 15 10 5 0 0
TYPICAL FORWARD
VOLTAGE VS. FORWARD CURRENT AT 25°C
SP250F SP200F
...