Operating Temperature Range Rated
Voltage Range Capacitance Range Capacitance Tolerance Leakage Current Dissipation Factor (at 20°C, 120Hz) -40~+105°C (250~400WV: -25~+105°C) 10 ~ 400V 39 ~ 22000uF ±20% (at 20°C, 120Hz) 0.01CV or 1.5mA whichever is smaller (at 20°C, after 5 minutes) C: Nominal Capacitance (uF) V: Rated
Voltage (V) Rated
Voltage(V) tan δ 10 0.45 16 0.35 25 0.30 35 0.25 50 0.20 63~100 160~200 250~400 0.15 0.12 0.15
Temperature Characteristics (Impedance Ratio at 120Hz)
W.V Z(-25°C)/Z(+20°C) Z(-40°C)/Z(+20°C)
10~16 4 15
25 3 10
35 3 8
50~63 2 6
80~100 2 5
160~200 250~400 3 4 6
Load Life (+105°C)
Time Capacitance Change Dissipation Factor Leakage Current
3000 hours Within± 20% of the initial value 200% of the specified value or less The specified value or less
Shelf Life (+105°C)
After storage for 500 hours at 105°C with no
voltage applied, the capacitor shall meet the specified limits of “Load Life”. After Test: UR to be applied for 60 minutes, 24 to 48 hours before measurement.
Frequency Coefficient
Freq(Hz) 50 Rated
Voltage(V) 50 0.95 63~100 0.95 160 0.90 120 1 1 1 1K 1.10 1.16 1.20 10K 1.15 1.30 1.50 20K 1.15 1.33 1.55
Temperature Coefficient
Temperature(°C) Factor +40 2.7 +55 2.5 +70 2....