supply. SPX-6250-GP1 Datasheet

SPX-6250-GP1 Datasheet PDF

Part SPX-6250-GP1
Description Power supply
Feature SUNPOWER TECHNOLOGY CORP. 16F.-1, No.150, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan .
Manufacture SUNPOWER
Datasheet
Download SPX-6250-GP1 Datasheet

SUNPOWER TECHNOLOGY CORP. 16F.-1, No.150, Jian 1st Rd., Zho SPX-6250-GP1 Datasheet




SPX-6250-GP1
SUNPOWER TECHNOLOGY CORP.
16F.-1, No.150, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.).
TEL: 886-2-8226-3100
FAX: 886-2-8226-3111
http://www.sunpower.com.tw
E-mail: sunpower@sunpower.com.tw
SPX-6200-GP1/SPX-6250-GP1
200W/250W, Six Output
For 1U System
ATX12V Power supply
180 x 100 x 40.5 mm
7.09 x 3.94 x 1.60 inch
CB
Features:
Universal full range AC input with active PFC, P.F.> 0.95
High efficiency and reliability
Altitude during operation up to 4000M
Built-in long life ball bearing fan
3.3V & 5V VRM design
Over voltage, over load & short circuit, over current, over temperature protection
With power good signal & PS-ON signal output
Meet Intel ATX 2.01 / ATX2.31 / ATX 12V
3 years warranty
Specification:
Voltage
90V ~ 264VAC universal full range or 127V ~ 375VDC
Frequency
47 ----- 63 Hz.
Current SPX-6200-GP1 <2.8A @ 100VAC input, full load condition
INPUT
SPX-6250-GP1 <3.5A @ 100VAC input, full load condition
Inrush Current(TYP.) 40A@115V , 60A@230V AC input, Cold start, at 25ambient
Leakage Current <1.5mA@264V AC input
Power Factor
PF 0.95
Voltage
5V 3.3V 12V -12V -5V 5Vsb
Min Load
0.3A 0A 0.2A 0A 0A 0A
OUTPUT
Max SPX-6200-GP1
Load SPX-6250-GP1
Output Tolerance
RippleNoiseMAX.
20A
±3%
70mV
25A
±5%
70mV
12A
16A
±3%
120mV
0.5A
Peak Load 1.5A
±10%.
120mV
0.5A
±5%
100 mV
3A
±5%
70 mV
Efficiency (TYP.)
83%
Output MAX.
SPX-6200-GP13.3V & 5V max 110W, total output max 200W
SPX-6250-GP13.3V & 5V max 110W, total output max 250W
Over Voltage
5.4V~6.8V
3.7V~4.1V 13.1V~14.5V
----
----
----
Shutdown and latch off, recover after re-start up.
PROTECTION
Over current (MAX)
30A
30A
20A ----
----
----
OverLoad ShortCircuit
When power supply over 105%~ 150% max load or short circuit acted, power supply will be shutdown and
latch off, recover after re-start up.
Over Temperature Over 95± 5Shutdown, recovers automatically after fault condition has been removed.
Rise time
<20mS
ELEC. CHAR.
Hold up time
Power Good signal
>16mS@230V
Power on within 100~500ms, high level TTL signal release.
PS-ON signal
Temperature
P/S ON: PS-ON=Low or <0.8V, P/S OFF: PS-ON=Hi or >2V
Operating: -10~70; De-rating: 50~70: 2.5%/. ; Storage: -20~+85
ENVIRONMENT Humidity
Operating: 20% ~ 90% RH (non condensing) ; Storage: 10% ~ 95% RH (non condensing)
Altitude
13124ft ( 4000m ) operating
Withstand voltage I/P-O/P:3.0KVAC, I/P-PE:1.5KVAC, 1minute
SAFETY
Isolation resistance I/P-O/P, I/P-PE 100MΩ/500VDC at 25/ 70% RH
Safety standard
UL 60950-1 2nd,CSA C22.2 No. 60950-1- 07 2nd ,TUV EN 60950-1:2006+A11+A1+A12+A2,IEC 60950-1:2005+A1+A2,
approved
EMI EN 55032 CLASS B, FCC CFR 47 PART 15 CLASS B, CNS 13438 CLASS B.
EMC Compliance to EN61000-3-2 CLASS D, EN61000-3-3
EMS EN 55024EN 61000-4-2,3,4,5,6,8,11
Cooling
Forced airflow cooling with a DC fan.
OTHERS
M.T.B.F.
Dimension
108.7 K hours
180 x 100 x 40.5 (L*W*H)
PACKING
N.W.: 1.17 KG / 1PC; 12 PCS / 2.02 CUFT / 1 CTN
All measurements which not mentioned are based on 230VAC input, output max at ambient 25/ 70%RH
Output tolerance included set up voltage, line regulation and load regulation.
NOTE
The regulation is measured between 20%-100% max load of each output, Total output t must under output Max.
Ripple & noise are measured at 1050condition and 20MHz of bandwidth by using a 10〞〜15twisted pair-wire terminated
with a 0.1uF & a 10uF parallel capacitor.
The operating temperature shall follow the de-rating curve in spec
The output load may be requested for decreasing as de-rating curve in spec when low input voltage is under 100VAC
The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives.
33duty cycle maximum within every 10 seconds, average output power should not exceed the Max. load
7 Start up steps : Connect AC or DC source, before you turn on the power supply. The unit can’t be operated by PS-ON and GND are shorted
before power supply turns on. Please contact us for different requirement.
Copy Right Sunpower Technology Corp. 2009, All Rights Reserved.
Specifications subject to change without notice.
QR0405-1 Rev,:1.0
SPX-6200-GP1&SPX-6250-GP1 Rev 2.1
RS-100075 MAY-24-2017



SPX-6250-GP1
SUNPOWER TECHNOLOGY CORP.
16F.-1, No.150, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.).
TEL: 886-2-8226-3100
FAX: 886-2-8226-3111
http://www.sunpower.com.tw
E-mail: sunpower@sunpower.com.tw
SPX-6200-GP1/SPX-6250-GP1
De-rating Curve
Output De-rating Vs Input Voltage
Ta=25
100
100
90
80 80
60 70
50
40 60
50
20
40
-10 0 10 20 30 40 50 60 70
AMBIENT TEMPERATURE( )
Dimension:
(HORIZONTAL)
90 100 110 120 ~ 230 240 250 264
INPUT VOLTAGE (VAC) 60Hz
(Unit: mm)
SPX-6200-GP1/SPX-6250-GP1
PIN7
PIN4
Copy Right Sunpower Technology Corp. 2009, All Rights Reserved.
Specifications subject to change without notice.
QR0405-1 Rev,:1.0
SPX-6200-GP1&SPX-6250-GP1 Rev 2.1
RS-100075 MAY-24-2017




@ 2014 :: Datasheetspdf.com ::