Ultrafast Recovery Rectifier
FEATURES ·Ultrafast Recovery Time ·Low Forward Voltage ·Low Leakage Current ·175℃ Operatin...
Ultrafast Recovery Rectifier
FEATURES ·Ultrafast Recovery Time ·Low Forward
Voltage ·Low Leakage Current ·175℃ Operating Junction Temperature ·Minimum Lot-to-Lot variations for robust device
performance and reliable operation
APPLICATIONS ·Switching power supplies ·Power switching circuits ·General purpose
ABSOLUTE MAXIMUM RATINGS(Ta=25℃)
SYMBOL
PARAMETER
VALUE UNIT
VRRM VRWM
VR
IF(AV)
Peak Repetitive Reverse
Voltage Working Peak Reverse
Voltage DC Blocking
Voltage
Average Rectified Forward Current (Rated VR)
600
V
5
A
IF(RMS)
RMS forward current
10
A
TJ
Junction Temperature
-65~175 ℃
Tstg
Storage Temperature Range
-65~175 ℃
STTH506B
isc website:www.iscsemi.com
1 isc & iscsemi is registered trademark
Ultrafast Recovery Rectifier
THERMAL CHARACTERISTICS
SYMBOL
PARAMETER
Rth j-c Thermal Resistance,Junction to Case
STTH506B
MAX 3.5
UNIT ℃/W
ELECTRICAL CHARACTERISTICS
SYMBOL
PARAMETER
CONDITIONS
IF= 5A ,Tc=25℃
VF*
Maximum Instantaneous Forward
Voltage
IF= 5A ,Tc=150℃
VRRM= 600V,Tc=25℃
IR
Maximum Instantaneous Reverse Current
VRRM= 600V ,Tc=150℃
trr
Maximum Reverse Recovery Time
IF = 0.5 A, Irr = 0.25 A, IR = 1 A, Tj = 25° C
*:Pulse test ,Pulse width=300us,duty cycle≤2%
MAX 1.85 1.4
5 130
UNIT V μA
30
ns
NOTICE: ISC reserves the rights to make changes of the content herein the datasheet at any time without notification. The information contained herein is presented only as a guide for the applications of our products. ISC produc...