ISDN U-BUS Input/Output Transformer
www.DataSheet4U.com
ISDN
U-BUS Input/Output Transformer
TEW4897
TEW4897 is designed to interface with the subscriber...
Description
www.DataSheet4U.com
ISDN
U-BUS Input/Output Transformer
TEW4897
TEW4897 is designed to interface with the subscribers premises (NT) and the 2- wire line side of the Central Office Equipment (LT) in the ISDN Network. TEW4897 meets the electrical requirements for the SIEMENS PEB20902/IEC (4B3T) device. Exceeds the requirements of: EN60950 and EN41003.
Applications: Low profile construction. Up to 50 mA line current. High insulation between line and equipment side.
MECHANICAL
1 6
DEVICE
2
LINE
7
3 4
DOT AT PIN #1
DIMENSIONS, Inches (mm)
P/N TEW4897 L W H A B C S 0.025 (0.64)
0.87 0.83 0.63 0.60 0.20 0.12 (22.0) (21.0) (16.0)(15.3) (5.1) (3.0)
TEW4897.chp
ELECTRICAL Line Impedance Inductance Leakage Inductance Distributed Capacitance Winding Resistance Turns Ratio Longitudinal Balance DC Capability (Line Side) Dielectric Strength 150 Ω > 3.7 mH < 12.5 µH < 110 pF < 2.5 Ω < 1.74 Ω 1 : 1.32 > 60 dB > 55 dB 50 mA 4000 V rms
97/08/25
(6-7) (6-7) (1-4) (1-4) (6-7) (6-7) : (1-4) 1 - 4 KHz 4 - 160 KHz
Issue; D
Filtran Limited
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3 Tel : (613) 226-1626 Fax : (613) 226-7124
4-12
...