HIGH-ENERGY TRIGGERED SPARK GAPS
Triggergaps
DESCRIPTION
CP Clare's Triggergaps are high-energy spark gaps that are cap...
HIGH-ENERGY TRIGGERED SPARK GAPS
Triggergaps
DESCRIPTION
CP Clare's Triggergaps are high-energy spark gaps that are capable of switching stored energy in a fraction of a microsecond. Triggergaps require no standby power, are extremely rugged, and require only a low-energy, high
voltage triggering pulse. The miniature TA series (1-15kV) provides switching capability for pulses with energy content as high as 50 joules. The larger TB series (2.5-25 kV) will reliably switch pulses with up to 300 joules of energy. The TG-221 to 226 (1-60 kV) can switch pulses with energy contents of up to 6000 joules and feature adjustable self-breakdown
voltages.
FEATURES
s Tight self-breakdown
voltage tolerance
APPLICATIONS
s s s s
(±10%;TA & TB series) s Adjustable self-breakdown
voltage (TG-221 to TG-226) s Rugged ceramic-metal construction s Refractory metal electrodes s Corrosion-resistant stainless steel external surfaces (TB series)
High current surge generators Exploding bridge wire systems Crowbars Flashtube triggers
STANDARD
VOLTAGES
Series or P/N TA Self-Breakdown
Voltage (typ) 1.0 2.0 5.0 7.0 10.0 15.0 2.5 5.0 10.0 15.0 20.0 25.0 1.0-20.0 18.0-40.0 1.0-20.0 18.0-40.0 35.0-60.0 kV kV kV kV kV kV kV kV kV kV kV kV kV kV kV kV kV Units
TB
TG-221 TG-222 TG-224 TG-225 TG-226
North America: 1-800-CPCLARE
Europe: 32-11-300868
Asia: 886-2-2523-6368
Japan: 81-3-3980-2212
558
HIGH-ENERGY TRIGGERED SPARK GAPS
Triggergaps
SPECIFICATIONS
All characteristics at 25˚C
TA-1.0
CONDITIONS
...