DatasheetsPDF.com

TT1202 Datasheet

Part Number TT1202
Manufacturers TEMCo
Logo TEMCo
Description Euro Standard Isolation Transformer
Datasheet TT1202 DatasheetTT1202 Datasheet (PDF)

Euro Standard Isolation Transformer TT1202-TT1211 KVA: Input Voltage: Output Voltage: Taps: Insulation Class: 15 - 750 575 Delta 415/400/380 Wye ± 5% FC (See Wiring Diagram) 220º C Phase: Frequency: BIL: Coils: Temp Rise: Three-Phase 50/60Hz 10 kV Copper 150º C NEMA 3R Outdoor Enclosure Full 10 Year Warranty European Output Voltages TEMCo Euro-Standard transformers are used to converter standard 3 phase U.S. voltages to standard 3 phase European voltages. This is useful when importing E.

  TT1202   TT1202






Part Number TT120N16SOF
Manufacturers Infineon
Logo Infineon
Description Phase Control Thyristor
Datasheet TT1202 DatasheetTT120N16SOF Datasheet (PDF)

Netz-Thyristor-Modul Phase Control Thyristor Module Technische Information / technical information TT120N16SOF Key Parameters VDRM / VRRM ITAVM ITSM VT0 rT RthJC Base plate Weight 1600 V 120 A (TC=85 °C) 32257500AA(TC=55°C) 0,9 V 3,35 mΩ 0,19 K/W 20 mm 75 g Merkmale  Löt-Löt Technologie  Industrie-Standard-Gehäuse  Elektrisch isolierte Bodenplatte Typische Anwendungen  Sanftanlasser  Gleichrichter für Antriebsapplikationen  Leistungssteller  Gleichrichter für UPS  Batterieladegleichr.

  TT1202   TT1202







Part Number TT1209
Manufacturers TEMCo
Logo TEMCo
Description Euro Standard Isolation Transformer
Datasheet TT1202 DatasheetTT1209 Datasheet (PDF)

Euro Standard Isolation Transformer TT1202-TT1211 KVA: Input Voltage: Output Voltage: Taps: Insulation Class: 15 - 750 575 Delta 415/400/380 Wye ± 5% FC (See Wiring Diagram) 220º C Phase: Frequency: BIL: Coils: Temp Rise: Three-Phase 50/60Hz 10 kV Copper 150º C NEMA 3R Outdoor Enclosure Full 10 Year Warranty European Output Voltages TEMCo Euro-Standard transformers are used to converter standard 3 phase U.S. voltages to standard 3 phase European voltages. This is useful when importing E.

  TT1202   TT1202







Part Number TT1208
Manufacturers TEMCo
Logo TEMCo
Description Euro Standard Isolation Transformer
Datasheet TT1202 DatasheetTT1208 Datasheet (PDF)

Euro Standard Isolation Transformer TT1202-TT1211 KVA: Input Voltage: Output Voltage: Taps: Insulation Class: 15 - 750 575 Delta 415/400/380 Wye ± 5% FC (See Wiring Diagram) 220º C Phase: Frequency: BIL: Coils: Temp Rise: Three-Phase 50/60Hz 10 kV Copper 150º C NEMA 3R Outdoor Enclosure Full 10 Year Warranty European Output Voltages TEMCo Euro-Standard transformers are used to converter standard 3 phase U.S. voltages to standard 3 phase European voltages. This is useful when importing E.

  TT1202   TT1202







Part Number TT1207
Manufacturers TEMCo
Logo TEMCo
Description Euro Standard Isolation Transformer
Datasheet TT1202 DatasheetTT1207 Datasheet (PDF)

Euro Standard Isolation Transformer TT1202-TT1211 KVA: Input Voltage: Output Voltage: Taps: Insulation Class: 15 - 750 575 Delta 415/400/380 Wye ± 5% FC (See Wiring Diagram) 220º C Phase: Frequency: BIL: Coils: Temp Rise: Three-Phase 50/60Hz 10 kV Copper 150º C NEMA 3R Outdoor Enclosure Full 10 Year Warranty European Output Voltages TEMCo Euro-Standard transformers are used to converter standard 3 phase U.S. voltages to standard 3 phase European voltages. This is useful when importing E.

  TT1202   TT1202







Part Number TT1206
Manufacturers TT Semiconductor
Logo TT Semiconductor
Description High-CMRR Balanced Input Line Receiver
Datasheet TT1202 DatasheetTT1206 Datasheet (PDF)

InGeniusâ High-CMRR Balanced Input Line Receiver ICs TT1200 Series FEATURES · High CMRR: typ. 90 dB at 60 Hz · Extremely high common-mode input impedance · Maintains balance under real-world conditions · Transformer-like performance in an IC · Excellent performance · Wide bandwidth: typ. > 22 MHz · High slew rate: typ. 12 V/us · Low distortion: typ. 0.0005 % THD · Low noise: typ. -107 dBu · Several gains: 0 dB, -3 dB, & -6 dB APPLICATIONS · Balanced Audio Line Receivers · Instrumentation Ampli.

  TT1202   TT1202







Euro Standard Isolation Transformer

Euro Standard Isolation Transformer TT1202-TT1211 KVA: Input Voltage: Output Voltage: Taps: Insulation Class: 15 - 750 575 Delta 415/400/380 Wye ± 5% FC (See Wiring Diagram) 220º C Phase: Frequency: BIL: Coils: Temp Rise: Three-Phase 50/60Hz 10 kV Copper 150º C NEMA 3R Outdoor Enclosure Full 10 Year Warranty European Output Voltages TEMCo Euro-Standard transformers are used to converter standard 3 phase U.S. voltages to standard 3 phase European voltages. This is useful when importing European Machinery into the U.S. Additionally, these transformers are rated for either 50Hz or 60Hz, allowing them be connected in reverse to convert European voltages to U.S. voltages when importing U.S. machinery into Europe. Either way, these transformers are built to last, guaranteed! That’s why we back these with a decade long warranty. Don’t have floor space to mount your TEMCo EuroStandard transformer? No problem! Heavy duty wall mounting brackets are supplied on all Euro-Standard transformers up to 45KVA. For larger units, take advantage of the weather shields included with every unit and mount your Euro-Standard transformer outside. Save your valuable floor space for your machinery instead of cluttering it with electrical equipment. Connections are made simple with TEMCo EuroStandard transformers. Multiple taps are provided on the output for 380, 400, or 415v Wye configured outputs. All your input and output connections can be made via the provided fast connection lugs. Rigid .


2015-02-02 : K2733    SIM300    SDNT0603    SDNT1005    SDNT1608    SDNT2012    SDNT1005    SDNT1608    SDNT2012    TT1202   


@ 2014 :: Datasheetspdf.com ::