Qingxian Zeming Langxi Electronic
www.micro-transformer.com
ZMCT103C Current Transformer
Small size,high accuracy,good...
Qingxian Zeming Langxi Electronic
www.micro-transformer.com
ZMCT103C Current Transformer
Small size,high accuracy,good consistency,for current and power measurement
Structural parameters:
Remarks: primary input: straight- through type( make the measured circuit be through the hole) 1、2pin :secondary output
Front view
Bottom view
The main technical parameters:
model input current
ZMCT103C 0-10A(50Ω)
Rated output current turns ratio
phase angle error Accuracy class linearity Permissible error isolation
voltage application
5mA at input 5A
1000:1 ≤15' (input 5A,sampling resistor 50Ω)
0.2
≤0.2%(5%dot~120%dot) -0.2%≤f≤+0.2%
(input 5A,sampling resistor50Ω) 4500V
Precise measurement of current and power
Encapsulation installation
operating temperature
Epoxy PCB mounting(Pin Length>3mm)
-40℃~+85℃
Tel: 86-25-52601870
Fax: 86-25-52633420
E-mail:
[email protected]
Qingxian Zeming Langxi Electronic
Direction for use:
www.micro-transformer.com
Figure Ⅰ
FigureⅡ
1. The typical usage of the product is for the active output (Figure Ⅰ). R is a sampling resistor 2. The product can be directly through the resistance sampling, easy to use (FigureⅡ).