DatasheetsPDF.com

ISH1215A Dataheets PDF



Part Number ISH1215A
Manufacturers XP Power
Logo XP Power
Description DC-DC Converter
Datasheet ISH1215A DatasheetISH1215A Datasheet (PDF)

ISH Series 2 Watts • xxxSingle Output Series • SMD Package • Industry Standard Pinout • Operating Temperature 40 °C to +105 °C • 1500 VDC Isolation, 3000 VDC Option • 3 Year Warranty DC-DC Converter Models & Ratings Input Voltage 4.5-5.5 10.8-13.2 13.5-16.5 21.6-26.4 Output Voltage 3.3V 5V 9V 12V 15V 5V 9V 12V 15V 24V 15V 5V 12V 15V 24V Output Current 400 mA 400 mA 222 mA 167 mA 133 mA 400 mA 222 mA 167 mA 133 mA 83 mA 133 mA 400 mA 167 mA 133 mA 83 mA Input Current(2) No Load Full Load .

  ISH1215A   ISH1215A


Document
ISH Series 2 Watts • xxxSingle Output Series • SMD Package • Industry Standard Pinout • Operating Temperature 40 °C to +105 °C • 1500 VDC Isolation, 3000 VDC Option • 3 Year Warranty DC-DC Converter Models & Ratings Input Voltage 4.5-5.5 10.8-13.2 13.5-16.5 21.6-26.4 Output Voltage 3.3V 5V 9V 12V 15V 5V 9V 12V 15V 24V 15V 5V 12V 15V 24V Output Current 400 mA 400 mA 222 mA 167 mA 133 mA 400 mA 222 mA 167 mA 133 mA 83 mA 133 mA 400 mA 167 mA 133 mA 83 mA Input Current(2) No Load Full Load 30 mA 506 mA 30 mA 506 mA 30 mA 506 mA 30 mA 506 mA 30 mA 506 mA 25 mA 212 mA 25 mA 212 mA 25 mA 212 mA 25 mA 212 mA 25 mA 212 mA 18 mA 169 mA 15 mA 105 mA 15 mA 105 mA 15 mA 105 mA 15 mA 105 mA Notes 1. For optional 3000 VDC isolation add suffix ‘-H’ to end of part number e.g. ISH1224A-H. 2. Input currents measured at nominal input voltage. 3. Typical value at full load. Dimensions: ISH: 0.500 x 0.44 x 0.285” (12.7 x 11.2 x 7.25 mm) Maximum Capacitive Load 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF 220 µF Efficiency(3) 72% 79% 82% 82% 83% 79% 82% 82% 83% 84% 83% 79% 82% 83% 86% Model Number(1) ISH0503A ISH0505A ISH0509A ISH0512A ISH0515A ISH1205A ISH1209A ISH1212A ISH1215A ISH1224A ISH1515A ISH2405A ISH2412A ISH2415A ISH2424A Mechanical Details 0.441±0.012 (11.20±0.30) 0.327 (8.30) 0.285 (7.25) 0.276 (7.00) 0.500±0.020 (12.70±0.5) 0.300 (7.62) Top View 0.024 (0.60) 0.035 (0.88) A 0.010 (0.25) Recommended Footprint Top View grid: 0.1 x 0.1 in (2.54 x 2.54 mm) Side View 0.100 0.010 (2.54) (0.25) A 8 12 5 4 0.039 (1.00) 0.100 (2.54) 5 .00 º 0.480 (12.20) PIN CONNECTIONS Pin Function 1 GND 2 +Vin 4 0V 5 +Vout 8 No Connection Notes 1. All dimensions are in inches (mm) 2. Weight: 0.003 lbs (1.5 g) typical. 3. Pin diameter: 0.02 ±0.002 (0.5 ±0.005) 4. Pin pitch and length tolerance: ±0.014 (±0.35) 5. Case tolerance: ±0.02 (±0.5) 1 www.xppower.com ISH Series Input Characteristic Input Voltage Range Input Current Input Reflected Ripple Input Surge Input Filter Minimum 4.50 10.80 13.50 21.60 Capacitor Typical 15 DC-DC Converter Maximum 5.50 13.20 16.50 26.40 9 18 21 30 Units VDC VDC VDC VDC mA pk-pk VDC for 1 s VDC for 1 s VDC for 1 s VDC for 1 s Notes & Conditions 5 V nominal 12 V nominal 15 V nominal 24 V nominal See Models and Ratings table Through 12 µH inductor and 47 µF capacitor 5 V models 12 V models 15 V models 24 V models Output Characteristic Output Voltage Initial Set Accuracy Minimum Load Line Regulation Load Regulation Start Up Delay Ripple and Noise Transient Response Short Circuit Protection Maximum Capacitive Load Temperature Coefficient Minimum 3.3 10 Typical 2 100 Maximum 24 -7.5, +2.5 ±1.2 3 220 0.03 Units VDC % % % % ms mV pk-pk % deviation µF %/˚C Notes & Conditions See Models and Ratings table At 70% load Per 1% change of input voltage (±1.5% for 3V3 output) See graph 20 MHz bandwidth, measured using 0.1 µF capacitor Recovery to within 1% in 500 µs for a 25% load change (5% max. deviation for 3.3 & 5 V models) Continuous, with auto recovery, except 1 s max for 24 input V models General Characteristic Efficiency Isolation: Input to Output Switching Frequency Isolation Resistance Isolation Capacitance Power Density Mean Time Between Failure Weight Minimum 1500 50 109 3500 Typical 20 0.003 (1.5) Maximum 300 31.8 Units VDC kHz Ω pF Win3 kHrs lb (g) Notes & Conditions See Models and Ratings table For optional high isolation versions, 3000 VDC input to output add suffix -H to model number Input to output, tested at 500 VDC Input to output MIL-HDBK-217F, +25 °C GB Environmental Characteristic Operating Temperature Storage Temperature Case Temperature Operating Humidity Cooling Minimum -40 -55 Typical Maximum +105 +125 +115 95 Units °C °C °C % RH Notes & Conditions Derate from 100% load at +100 °C to 80% load at 105 °C Non-condensing Natural convection www.xppower.com 2 ISH Series EMC: Emissions Phenomenon Conducted Radiated EMC: Immunity Phenomenon ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Fields Load Regulation Standard EN55022 EN55022 Standard EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 DC-DC Converter Test Level Class B Class B Notes & Conditions See Application Note for Class B filter See Application Note for Class B filter Test Level 3 3 V/m 2 2 3 V rms 1 A/m Criteria B A B B A A Notes & Conditions External input capacitor required, 330 µF/100 V External input capacitor required, 330 µF/100 V Output Voltage Accuracy (%) Output Voltage Accuracy (%) 115 105 Typical Load Curve 100 0 50 70 Load (%) For 3.3 V output models +2.5% -2.5% -7.5% 100 110 105 Typical Load Curve 100 0 50 70 Load (%) For all other models +2.5% -2.5% -7.5% 100 Application Note EMI Filter for Class B Emissions 4.7 µF, 50 V 6.8 µH 4.7 µF, 50 V + Vin + Vout ISH -Vin 0 V C Load For ISH2424A model only, add Ycap, 470 µF, 3 kv .


ISH1212A ISH1215A ISH1224A


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)