40 Amp Power Relay
40 Amp Power Relay with AC Coils & Low Case Profile QC Terminals PTRA-T
Load Type
E86876
Voltage 1 Form A
120 VAC* 2...
Description
40 Amp Power Relay with AC Coils & Low Case Profile QC Terminals PTRA-T
Load Type
E86876
Voltage 1 Form A
120 VAC* 240 VAC
40 A 30 A
1 Form B (SPDT-NC)
30 A
20 A
1 Form C NO NC 40 A 30 A 30 A 20 A
General Purpose 277 VAC 30 A
20 A 30 A 20 A
Resistive 250K Cycles 100K Cycles
Motor Ballast
280 VAC
30 VDC* 240 VAC 240 VAC 277 VAC 30 VDC 250 VAC 120 VAC*
280 VAC
5A 40 A 40 A 20 A 25 A
40 A* 2 HP 1 HP
5A
5A
30 A 30 A —— —— 30 A 1.5 HP —— 5A
5A 40 A 40 A 20 A 25 A
40 A* 2 HP 1 HP
5A
5A
30 A 30 A —— —— 30 A 1.5 HP —— 5A
Lamp Load TV-5 120 VAC 5 A
—— 5 A ——
LRA/FLA* *Not UL
240 VAC 80 A/30 A 120 VAC 96 A/30 A
—— 80 A/30 —— —— 96 A/30 ——
FEATURES
Power PCB Relay with AC Coils 40 Amp 240 VAC Resistive UL Rating 2 HP 250 VAC Rating Two Version:
T2 (1A), T3 (1C) PC Pins & QC Pins T4 (1A), T5 (1C) QC Pins with Mounting Tabs
UL Class F Insulation Standard
Meets UL 508 and UL 873 Spacing RoHS Compliant
CONTACT DATA
Material Initial Contact Resistance
AgCdO, AgSnO2 30 mΩ Max. @ 1 A, 6 VDC
Maximum Switching Voltage
110 VDC, 300 VAC
Maximum Switching Current
40 A
Maximum Switching Power
1,200 W, 10,000 VA
Service Life
Mechanical Electrical
1 x 107 Operations 1 x 105 Operations
Meets UL 508 and UL 873 Spacing - 3.18 mm Through Air, 6.36 mm Over Surface.
ORDERING INFORMATION
Example:
PTRA -1C -12 E T
Model: PTRA (PTRA-OT)
Contact Form: 1A, 1B, 1C
-T5
Coil Voltage: 12, 24, 110, 120, 220 Enclosure: T2 & T3 C: Dust Cover; S: Sealed
T4 & T5...