Feature MAMF-011024; MAMF-011024 Transceiver 21 - 27 GHz Features  Conversion Gain: TX = 3 dB RX = 11 dB  Receive: Noi.
Manufacture MA-COM
Datasheet
Download MAMF-011024 Datasheet




MA-COM MAMF-011024
MAMF-011024
Transceiver
21 - 27 GHz
Features
Conversion Gain:
TX = 3 dB
RX = 11 dB
Receive:
Noise Figure = 3 dB
IIP3 = +5 dBm
Transmit: IM3 = -40 dBc @ 0 dBm
LO: 8 - 10 GHz & 0 dBm Drive
Wide IF Bandwidth = 0.1 - 6.0 GHz
Single 5 Volt DC Bias, 180 mA
Lead-Free 4 mm 24-lead PQFN Package
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
The MAMF-011024 is a 21 - 27 GHz transceiver IC.
It integrates an LNA, PA, TX/RX switch, bi-directional
mixer, filtering, and LO frequency x2 multiplier with
amplification. This device is assembled in a lead-free
4 mm 24 lead PQFN surface mount plastic package.
This transceiver operates either in receive or in
transmit TDD (Time Division Duplex) mode. Receive
and transmit circuitry can be turned off during
transmit and receive, respectively. The TX/RX switch
can be operated independently of the power up
timing. It is powered from a single positive 5 V bias.
The MAMF-011024 is ideally suited for unlicensed
24 GHz ISM band applications.
Ordering Information1,2
Part Number
Package
MAMF-011024 -TR0500
500 piece reel
MAMF-011024 -SMB
Sample Test Board
1. Reference Application Note M513 for reel size information.
2. All sample boards include 3 loose parts.
Functional Schematic
Rev. V1
24 23 22 21 20 19
GND 1
18 GND
TX_OUT
GND
2
3
TXRF
LO 17 LOIN
16 GND
RX_IN
GND
4
5
RXRF
15 GND
14 IFIN/OUT
N/C 6
13 GND
7 8 9 10 11 12
Pin Configuration3
Pin No. Description Pin No. Description
1 Ground 13 Ground
2 Transmit Output 14 IF Input / Output
3 Ground 15 Ground
4
Receive Input
16
Ground
5
Ground
17 LO Input
6
No Connection
18
Ground
7
No Connection
19 LO Drain Voltage
8 RX Bias Adjust 20 No Connection
9 RX Drain Voltage 21 No Connection
10 RX Switch Control 22
TX Bias Adjust
11 TX Switch Control 23
No Connection
12 LO Bias Adjust 24 TX Drain Voltage
254 Ground
*Restrictions on Hazardous Substances,
European Union Directive 2011/65/EU.
3. MACOM recommends connecting all “No Connection” pins to
ground.
4. The exposed pad centered on the package bottom must be
connected to RF, DC and thermal ground.
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support



MA-COM MAMF-011024
MAMF-011024
Transceiver
21 - 27 GHz
Rev. V1
Electrical Specifications: TA = 25°C, RF = 24 GHz, IF = 5.6 GHz, LO = 9.2 GHz, 0 dBm,
Z0 = 50 Ω, VDT = VDR = VDLO = 5 V, Control / Bias Adjust Voltages5 = 0 / 5 V
Parameter
Test Conditions
Units
Min.
Typ.
Max.
LO: Drive Power
dBm
0
LO: Return Loss
dB 12
RX: Down Conversion Gain
RX: Noise Figure
dB 9
11
dB 3
RX: Return Loss
RX: Input IP3
RX: LO Isolation
TX: Up Conversion Gain
TX: Output Noise
TX: Return Loss
TX: Output IM3
TX: LO Isolation
IF: Return Loss
Isolation
Current
(sum of all DC currents)
5. See Truth Table.
LO to IF port
LO Frequency
2xLO Frequency
3xLO Frequency
+5 dBm POUT
LO to TX port
LO Frequency
2xLO Frequency
3xLO Frequency
TX Mode, RX to IF
RX Mode, TX to IF
TX Mode
RX Mode
Standby Mode
dB 11
dBm
+5
dB
22
33
55
dB 1
3
dBm/Hz -85
dB 15
dBc -40
dB
48
20
25
dB 7
dB
69
58
110 150 170
mA 120 160 180
<1
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support



MA-COM MAMF-011024
MAMF-011024
Transceiver
21 - 27 GHz
Absolute Maximum Ratings6,7
Parameter
Absolute Maximum
Input Power (RX)
Input Power (LO, IF)
+15 dBm
+10 dBm
Voltage
6V
Junction Temperature
150°C
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
7. MACOM does not recommend sustained operation near these
survivability limits.
Rev. V1
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
Truth Table
Mode / Pin
RX
TX
Standby
VBLO
(V)
+5
+5
0
VBT
(V)
0
+5
0
VBR
(V)
+5
0
0
VCT
(V)
0
+5
0
VCR
(V)
+5
0
0
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)