A3800
AC LINE FREQUENCY TIMER
June 2004
FEATURES: Selectable Timing Intervals Internal Voltage
Regulator Schmitt Trigger on all inputs for high noise immunity Power-On-Reset Built-in discharge when power is removed Output to drive an SCR connected to load Output to flash an indicator when timeout has occurred LS6301 (DIP); LS6301-S (SOIC) - See Figure 1
DESCRIPTION: The circuit operates by counting AC power line cycles. When the selected timeout occurs, the circuit will switch an external power device. Selectable timing intervals using 3 mode pins are indicated in Table 1. The circuit contains a Power-On-Reset (POR) to zero out all the timing counters upon power-up. A positive or negative transition of any of the A, B or C timing mode input pins will cause the timer to reset and begin again. Once time-out is achieved, it remains latched until a mode pin transition occurs or POR occurs.
TABLE 1. TIMING INTERVALS (60 Hz INPUT)
A INPUT B INPUT C INPUT TIMING I NTERVAL
Vss Vss
Vss 15 Minutes
Vss Vss
VDD 2 Minutes
Vss VDD
Vss 30 Minutes
Vss VDD
VDD 45 Minutes
VDD Vss
Vss 30 Seconds
VDD Vss
VDD 15 Minutes
VDD
VDD
Vss 1 Hour
VDD
VDD
VDD 2 Hours
PIN ASSIGNMENT - TOP VIEW
B1
OUT 1 2
OUT 2 3
VSS (+V) 4
FIGURE 1
LS6301
LSI
8 VDD (-V) 7 AC IN 6A 5C
The C input mode pin contains an internal pull up resistor for direc...