DatasheetsPDF.com

TH406 Dataheets PDF



Part Number TH406
Manufacturers Panasonic
Logo Panasonic
Description HOUR METER
Datasheet TH406 DatasheetTH406 Datasheet (PDF)

DIN48 DUAL INDICATOR HOUR METER TH40 Hour Meters 80.5 3.169 48 1.890 48 1.890 Silver panel mm inch Black panel RoHS Directive compatibility information http://www.nais-e.com/ Features 1. Upgraded composite function Specified-period measurement and total-time measurement can be monitored on a single hour meter. 2. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer period of measurement. 3. Common for 50/60 Hz power frequency A lever is .

  TH406   TH406


Document
DIN48 DUAL INDICATOR HOUR METER TH40 Hour Meters 80.5 3.169 48 1.890 48 1.890 Silver panel mm inch Black panel RoHS Directive compatibility information http://www.nais-e.com/ Features 1. Upgraded composite function Specified-period measurement and total-time measurement can be monitored on a single hour meter. 2. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer period of measurement. 3. Common for 50/60 Hz power frequency A lever is used to select 50 Hz or 60 Hz. There is no need to rearrange the control panel and other signal destinations. 4. Dimensions as per DIN 43700 standard The units are in the 48 × 48 DIN standard size. They can be fitted in panels and give refined metallic appearance. 5. Easier wiring The flat terminals (#187) are quick and easy to connect. 6. Rotary indicator The rotary indicator makes one turn every 2 minutes for monitoring. 7. Compliant with CE. Specifications Rated operating voltage Allowable operating voltage range Rated frequency Counting range Minimum time display Rated power consumption Insulation resistance (Initial value) Breakdown voltage (Initial value) Max. temperature rise Vibration resistance Functional Shock resistance Functional Destructive Ambient temperature Ambient humidity Weight 12 V AC, 24 V AC, 48 V AC, 100 V AC, 110 V AC, 115 to 120 V AC, 200 V AC, 220 V AC, 240 V AC 85 to 115% of rated operating voltage 50/60 Hz (selectable by switch) 0 to 9999.9 hours (upper side) ... with reset indicator 0 to 99999.9 hours (lower side) ... without reset indicator 0.1 hours (6 min) Approx. 1.5 W Min. 100 MΩ; Between live and dead metal parts (At 500V DC) 2,000 Vrms Between live and dead metal parts 55°C 131°F 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) Min 98 m/s2 {10 G} (4 times on 3 axes) Min 980 m/s2 {100 G} (5 times on 3 axes) –10 to +50°C +14 to +122°F Max. 85% RH (non-condensing) 160 g 5.64 oz Product types Type TH40 series Operating voltage 100V AC 200V AC 12V AC Part number Silver panel Black panel TH401S TH401 TH402S TH402 TH403S TH403 Operating voltage 24V AC 48V AC 110V AC Part number Silver panel Black panel Operating voltage Part number Silver panel Black panel TH404S TH404 115 to 120V AC TH407S TH407 TH405S TH405 220V AC TH408S TH408 TH406S TH406 240V AC TH409S TH409 170 TH40 Applicable standard Safety standard EN61010-1 (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity EMC RF electromagnetic field immunity EFT/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/Instantaneous stop/Voltage fluctuation immunity Dimensions Pollution Degree 2/Overvoltage Category II EN55011 Group1 ClassA EN55011 Group1 ClassA EN61000-4-2 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95% (rated voltage) mm inch General tolerance: ±1.0 ±.039 Reset button Ⅺ48 Ⅺ1.890 Accumulated hours indicator (with reset indicator) Total accmulated hours indicator (without reset indicator) Case Mounting bracket (supplied) No.187 quick connect terminal (4.7 × 6.0 × 0.5) Decorative (.185 × .236 × .020) nut 50 1.969 60Hz Ⅺ44.8 Ⅺ1.764 Rotary indicator 5.5 .217 75 2.953 94 3.701 50Hz Frequency setting switch Wiring diagram M Panel mounting Panel Mounting Case bracket (supplied) Decorative nut 50 1.969 • Panel cutout dimensions 45 +0.6 0 1.772 +.024 0 mm inch Operating power supply 5.5 .217 88.5 3.484 171 .


TH405 TH406 TH407S


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)