62-PMB-080-5-11 Data Sheet PDF | api





(Datasheet) 62-PMB-080-5-11 data sheet PDF

Part Number 62-PMB-080-5-11
Description Power Line Filters
Manufacture api
Total Page 2 Pages
PDF Download Download 62-PMB-080-5-11 Datasheet PDF

Features: Power Line Filters Single Stage 62-PMF & PMB Series Features I Space-saving, compact designs Tested and found to be IAW VDE 0565 Part 3 I Suitable for pr oducts that must conform to FCC regulat ions I Excellent attenuation for high voltage impulse I Metal case provides effective EMI shielding I Excellent fi ltering characteristics for both normal mode and common mode I Epoxy molded f or internal component reliability I St ructure provides effective shielding fo r noise generated externally and intern ally I Operating temperature: -25°C t o +85°C (including temperature rise, s ee graph on page PF63) Applications I Digital equipment I Computers and perip herals I Measuring instruments I Medica l equipment I Equipment requiring very high impulse attenuation I Factory auto mation equipment I Industrial equipment such as UPS, inverters and converters I Telecommunications equipment I Office automation equipment, such as copy and fax machines Circuit Diagram 1 CX R L1 2 CX CY 3 E CY 4 S.

Keywords: 62-PMB-080-5-11, datasheet, pdf, api, Power, Line, Filters, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute, Equivalent

62-PMB-080-5-11 datasheet
Power Line Filters
Single Stage
62-PMF & PMB Series
Features
I Space-saving, compact designs
Tested and found to be
IAW VDE 0565 Part 3
I Suitable for products that must conform
to FCC regulations
I Excellent attenuation for high voltage impulse
I Metal case provides effective EMI shielding
I Excellent filtering characteristics for both normal mode
and common mode
I Epoxy molded for internal component reliability
I Structure provides effective shielding for noise
generated externally and internally
I Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF63)
Applications
I Digital equipment
I Computers and peripherals
I Measuring instruments
I Medical equipment
I Equipment requiring very high impulse attenuation
I Factory automation equipment
I Industrial equipment such as UPS, inverters
and converters
I Telecommunications equipment
I Office automation equipment, such as copy
and fax machines
Circuit Diagram
1
CX
R
L1
2
CX
CY 3
E
CY
4
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
62-PMB-050-5-11
62-PMF-050-5-11
62-PMB-080-5-11
62-PMF-080-5-11
62-PMB-100-5-12
62-PMF-100-5-12
62-PMB-150-5-13
62-PMF-150-5-13
62-PMB-200-5-13
62-PMF-200-5-13
250VAC
Rated
Current
5A
8A
10A
15A
20A
Leakage Current
(Max.)
Capacitance
CY CX
0.1uF
.1uF
0.50mA
3300pF
.22uF
.33uF
Inductance
(L1)
14mH
Temperature
Rise (Max.)
7.0mH
4.2mH
30°C
2.2mH
1.8mH
35°C
45°C**
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces ( 250 grams)
* PMF - designates Fast-on terminals
PMB - designates Bolt-in terminals
** The temperature rise of 20 amp units can be decreased to 30°C
by mounting on 200 X 200 x 1.0(mm) steel chassis
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF62

62-PMB-080-5-11 datasheet   62-PMB-080-5-11 datasheet  






Index : 0  1  2  3   4  5  6  7   8  9  A  B   C  D  E  F   G  H  I  J   K  L  M  N   O  P  Q  R   S  T  U  V   W  X  Y  Z
@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)