Power Line Filters
Power Line Filters Single Stage
62-PMF & PMB Series
Features
I Space-saving, compact designs
Tested and found to be I...
Description
Power Line Filters Single Stage
62-PMF & PMB Series
Features
I Space-saving, compact designs
Tested and found to be IAW VDE 0565 Part 3
I Suitable for products that must conform to FCC regulations
I Excellent attenuation for high voltage impulse
I Metal case provides effective EMI shielding
I Excellent filtering characteristics for both normal mode and common mode
I Epoxy molded for internal component reliability
I Structure provides effective shielding for noise generated externally and internally
I Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF63)
Applications
I Digital equipment I Computers and peripherals I Measuring instruments I Medical equipment I Equipment requiring very high impulse attenuation I Factory automation equipment I Industrial equipment such as UPS, inverters
and converters I Telecommunications equipment I Office automation equipment, such as copy
and fax machines
Circuit Diagram
1
CX R
L1
2
CX
CY 3 E
CY 4
Specifications
Model*
Rated Voltage (@ 50/60Hz)
62-PMB-050-5-11 62-PMF-050-5-11 62-PMB-080-5-11 62-PMF-080-5-11 62-PMB-100-5-12 62-PMF-100-5-12 62-PMB-150-5-13 62-PMF-150-5-13 62-PMB-200-5-13 62-PMF-200-5-13
250VAC
Rated Current
5A 8A
10A
15A
20A
Leakage Current (Max.)
Capacitance CY CX
0.1uF
.1uF
0.50mA
3300pF
.22uF
.33uF
Inductance (L1)
14mH
Temperature Rise (Max.)
7.0mH 4.2mH
30°C
2.2mH 1.8mH
35°C 45°C**
Note: Test voltage: 1500VAC one minute, line to ground Insulation resis...