Document
Power Line Filters Single Stage
12-PMF Series
Features
I Space-saving, compact designs I Suitable for products that must conform
to FCC regulations I Excellent attenuation for high voltage impulse I Metal case provides effective EMI shielding I Excellent filtering characteristics for both normal mode
and common mode I Epoxy molded for internal component reliability I Structure provides effective shielding for noise
generated externally and internally I Operating temperature: -25°C to +85°C
Applications
I Digital equipment I Computers and peripherals I Measuring instruments I Medical equipment I Equipment requiring very high impulse attenuation I Factory automation equipment I Industrial equipment such as UPS, inverters
and converters I Telecommunications equipment I Office automation equipment, such as copy
and fax machines
Circuit Diagram
Circuit 1
Circuit 2
Circuit 3 Circuit 5
Circuit 4 Circuit 6
Specifications
Model
12-PMF-001-5-A 12-PMF-002-5-B 12-PMF-003-5-A 12-PMF-003-5-B 12-PMF-006-5-A 12-PMF-006-5-C 12-PMF-006-5-D 12-PMF-010-5-A 12-PMF-010-5-C 12-PMF-015-5-C 12-PMF-015-5-E 12-PMF-020-5-C 12-PMF-020-5-D 12-PMF-020-5-E
Rated Voltage (@ 50/60Hz)
120/250VAC
Rated Current
1A 2A 3A
6A
10A
15A
20A
Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max.
Leakage Current (Max.)
0.5mA
Circuit Diagram
1 2 4 2 4 1 6 2 3
5
Figure
A B A B A C D A
C
E C D E
Temperature Rise (Max.)
30°C
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF64
Power Line Filters Single Stage
12-PMF Series
Figure A
2.4 1.8 (62) (46)
Figure C
2.0 (52) 2.4 (63) 3.2 (82)
.86 (22)
2 .17 (8.8)
2.0 (52)
1.4 (37)
Dimensions in inches (mm)
Common Mode
.14 (3.8)
2.1 (54)
1.25 (32) 2.4 (62)
Figure D
2 - .18 (4.8)
.41 (10.5)
1.9 2.3 2.8 (50) (60) (10.5)
Figure B
1.7 (44) 2.2 (56) 3.2 (81)
2 .34 (8.8)
1.2 (30)
.78 (20)
Figure E
1.7 (4.5) (2X)
2.9 2.5 3.3 (74) (64) (85)
1.7 (44) 2.9 (74)
1.1 (28)
Normal Mode
2.0 (51) 3.1 (80)
1.4 (36)
Oscillator 50Ω
1 Filter 3 24
50Ω
50Ω Level Meter
Oscillator 50Ω
1 Filter 3 24 50Ω 50Ω
50Ω Level Meter
Insertion Loss (dB)
12-PMF-001;-002;-003;-006
80
70 12-PMF-001-5-A
60 12-PMF-002-5-B
50 12-PMF-003-5-B
40
30
12-PMF-003-5-A
12-PMF-006-5-A 12-PMF-006-5-C
20
10
0 0.1
0.2
12-PMF-006-5-D
0.5 1 2
5 10 20
Frequency (MHz)
50
12-PMF-001;-002;-003;-006
80
70 12-PMF-001-5-A
60 12-PMF-002-5-B
50 12-PMF-003-5-B
40
30
12-PMF-003-5-A
12-PMF-006-5-A 12-PMF-006-5-C
20
10
0 0.1
0.2
12-PMF-006-5-D
0.5 1 2
5 10 20
Frequency (MHz)
50
Insertion Loss (dB)
Insertion Loss (dB)
12-PMF-001;-002;-003;-006
80 12-PMF-001-5-A
70
12-PMF-006-5-C
12-PMF-006-5-A 60
12-PMF-006-5-D
50
40
30
20
10 0 0.1
0.2
12-PMF-003-5-B.