Document
SM5T17
Wideband Load Insensitive Mixer
Features
LO 50 TO 5000 MHz RF 50 TO 5000 MHz IF 50 TO 3000 MHz LO DRIVE +17 dBm (NOMINAL) INSENSITIVE TO SYSTEM LOAD MISMATCH HIGH INTERCEPT: +24 dBm (TYP.)
Description
The SM5T17 is a termination insensitive mixer, designed for use
in military, wireless and test equipment applications. The design
utilizes Schottky bridge quad diodes, broadband ferrite baluns and
internal loads to provide excellent performance without
degradation due to external VSWR mismatches. Environmental
screening available to MIL-STD-883, MIL-STD-202 or
MIL
-DTL-28837, consult factory.
Product Image
Rev. V2
Ordering Information
Part Number SM5T17
Package Surface Mount
Electrical Specifications: Z0 = 50 Lo = +17 dBm (Downconverter application only)
Parameter
Test Conditions
Typical Units
Guaranteed
+25ºC
-40º to +85ºC
SSB Conversion Loss (max) & SSB Noise Figure (max)
fR = 0.05 to 1.5 GHz, fL = 0.05 to 1.5 GHz, fI = 0.05 to 1.5 GHz fR = 1.5 to 3.0 GHz, fL = 1.5 to 3.0 GHz, fI = 0.05 to 3.0 GHz fR = 3.0 to 5.0 GHz, fL = 3.0 to 5.0 GHz, fI = 0.05 to 3.0 GHz
dB dB
dB
6.9 7.5
8.5
8.3 8.8
10.5
9.0 9.5
11.2
Isolation, L to R (min) Isolation, L to I (min)
fL = 0.05 to 1.0 GHz fL = 1.0 to 5.0 GHz
fL = 0.05 to 1.0 GHz fL = 1.0 to 5.0 GHz
dB 35 dB 33
dB 40 dB 35
25 23
32 25
23 21
30 23
Isolation, R to I (min)
fR = 0.05 to 5.0 GHz
dB 32
1 dB Conversion Comp. Input IP3 VSWR
fL = +17 dBm
fL = 0.05 to 5.0 GHz, fR = 0.05 to 5.0 GHz, fI = 0.05 to 3.0 GHz
R-Port fR = 0.05 to 5.0 GHz, L-Port fL = 0.05 to 5.0 GHz, I-Port fI =0.05 to 3.0 GHz
dBm dBm
+13
+24
1.6:1 1.5:1 1.4:1
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information.
For further information and support please visit: https://www.macom.com/support
SM5T17
Wideband Load Insensitive Mixer
Absolute Maximum Ratings
Parameter Operating Temperature Storage Temperature
Peak Input Power Peak Input Current
Absolute Maximum
-54ºC to +100ºC
-65ºC to +100ºC +27 dBm max @ +25ºC +23 dBm max @ +100ºC
50 mA DC
Outline Drawing: Surface Mount *
Rev. V2
Weight: 2 grams (0.07 oz.) max.
Dimensions are inches (millimeters) ±0.015 (0.38) unless otherwise specified.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information.
For further information and support please visit: https://www.macom.com/support
SM5T17
Wideband Load Insensitive Mixer
Rev. V2
M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale.
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information.
For further information and support please visit: https://www.macom.com/support
.